background image

                                                                                     

  

DIM 100

< 0.009 %

< 0.005 %

3.15 kHz, 15 kHz

11.

Frequency Response

vs

21 JUN 94 10:06:59

-21.00

-18.00

-15.00

-12.00

-9.000

-6.000

-3.000

0.0

3.0000

AMPL(dBr)

10

100

1k

10k

100k

FREQ(Hz)

1

2

1

2

Plot 1: HI/LO-Cut on        Plot 2: HI/LO-Cut off

12. Noise Interference

    - U(F) = external voltage un-weighted with B = 22 Hz … 22 kHz, effective value (IEC 268-1)
    - U(G) = noise voltage, frequency-weighting filter according to CCIR-468-3, quasi peak weighted (IEC 268-1)
    - U(A) = interference voltage A-weighted, dB(A), effective value (IEC 268-1)
    - Signal-to-noise ratio referenced to a nominal output voltage of 69.3 V (1200W/4ohms)
    - HI/LO-CUT ON, GND LIFT = GROUNDED, input sensitivity = 0 dBu

Interference

output voltage

S/N ratio

Equivalent input

interference

voltage

Equivalent input
interference level

Residual

interference

output voltage

U(F)

< 615µV

> 101 dB

< 6.9µV

< -101 dBu

< 435µV

U(G)

< 3.65mV

> 85.5 dB

< 41µV

< -85.5 dBu

< 1.55mV

U(A)

< 490µV

> 103 dB

< 5.5µV

< -103 dBu

< 345µV

13. Crosstalk

- at f = 1 kHz

< -70 dB

14.

DAMPING FACTOR

 - internal

>300

-

 

internal with f = 1 kHz

15. SLEW RATE

>40 V/µs

- internal

16.

Factory Defaults

Caution:

 make sure to ckeck these settings:

Function

Location

Control

State

Setting

Input Sensitivity L & P

86207/86211

Jumper J11/J21

plugged in

0 dBu

Limiter Off Switch

86207/86211

S102

open

Limiter on

Limiter Service

86207/86211

S101 / S201

open

Fan Service

86207/86211

S001

open

Input Routing

rear panel

slide switch

Dual/Stereo

Dual Mode

HI/LO-Cut Filter

rear panel

slide switch

on

Filter on

Bridged Mode

rear panel

slide switch

Normal

Dual Mode

Limiter

rear panel

slide switch

Slow

Limiter slow

CIR.GND to Chassis

rear panel

slide switch

Grounded

All manuals and user guides at all-guides.com

Содержание Plasma Series

Страница 1: ...P3000 PRECISION SERIES SERVICE MANUAL All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...t an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mai...

Страница 3: ...called soft start the power outputs are switched on delayed via relays An inrush current limiter circuit prevents the mains fuses from being blown Maximum precision is also guaranteed as regards mecha...

Страница 4: ...harge The product will be returned to the customer prepaid Exclusions and Limitations The Limited Warranty does not apply to a exterior finish or appearance b certain specific items described in the i...

Страница 5: ...DIMENSIONS BLOCK DIAGRAM All manuals and user guides at all guides com...

Страница 6: ...00 W 8 Channel BRIDGED 2 dBu 4 dBu 11 dBu 3000 W 4 Maximum input level 21 dBu C OUTPUT PROPERTIES nominal output power with THD 0 1 20 Hz 20 kHz MBW 80 kHz maximum output power at 1 kHz with THD 1 MBW...

Страница 7: ...15 kHz J CROSSTALK at f 1 kHz less than 70 dB K DAMPING FACTOR internal at f 1 kHz 300 at f 100 Hz 400 L SLEW RATE internal 40 V s M NOISE INTERFERENCE U F external voltage un weighted with B 22 Hz 22...

Страница 8: ...4 GND 4 Fan voltage 5 BIAS Cold Side 5 15 V 5 Service Fan Switch 6 BIAS Cold Side 6 heat sink temperature A B 6 Service Fan Switch 7 GND 7 U1 front end A 7 U1 front end B 8 floating voltage 8 U1 fron...

Страница 9: ...ERV 2 and CNASERV 3 for the power amplifier A or short circuited pins CNBSERV 2 and CNBSERV 3 for the power amplifier B 4 4 ADJUSTING THE METER INSTRUMENTS level control set all the way to its clockwi...

Страница 10: ...V 6 allows for testing the functioning of the fans During operation CNASERV 6 can be utilized to monitor the temperature of the heat sink FAN SPEED U DC CNASERV 6 U DC CNBSERV 4 Remarks Stufe 0 6 5 V...

Страница 11: ...s can be driven using a common signal source 8 Level BRIDGED MODE set the level control all the way to its fully clockwise position HI LOW CUT switch is ON as factory pre set BRIDGED MODE BRIDGED LIMI...

Страница 12: ...alent input interference level Residual interference output voltage U F 615 V 101 dB 6 9 V 101 dBu 435 V U G 3 65mV 85 5 dB 41 V 85 5 dBu 1 55mV U A 490 V 103 dB 5 5 V 103 dBu 345 V 13 Crosstalk at f...

Страница 13: ...All manuals and user guides at all guides com...

Страница 14: ...All manuals and user guides at all guides com...

Страница 15: ...All manuals and user guides at all guides com...

Страница 16: ...All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 17: ...All manuals and user guides at all guides com...

Страница 18: ...All manuals and user guides at all guides com...

Страница 19: ...All manuals and user guides at all guides com...

Страница 20: ...48951 mains cable USA 352268 STECKER NETZ 30A UL CSA mains connector 30amp US 349846 KABEL KONFEKT 8POL 0 680M ribbon cable assy 8way 349847 KABEL KONFEKT 10POL 0 800M ribbon cable assy 10way 351153 K...

Страница 21: ...07916 DIODZ BZX 55C 7V5 0 50W diode zener 7V5 D0003 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0004 307916 DIODZ BZX 55C 7V5 0 50W diode zener 7V5 D0005 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0006 3...

Страница 22: ...1837 Q0041 351982 TRANS MJL 1302 A transistor MJL 1302 A Q0042 331658 TRANS MJ 15023 transistor MJ 15023 Q0043 331658 TRANS MJ 15023 transistor MJ 15023 Q0044 331658 TRANS MJ 15023 transistor MJ 1502...

Страница 23: ...omponent PTC R0200 348966 WI SO NTC B57164 K101 J 52 safety component NTC R0201 348966 WI SO NTC B57164 K101 J 52 safety component NTC VR001 348674 WI TRI 250 00 OHM LIN pot trim 250 Ohm lin VR002 348...

Страница 24: ...8mm faston CN18B 343516 FL STECKER 4 8 0 5 connector 4 8mm faston CN19A 343516 FL STECKER 4 8 0 5 connector 4 8mm faston CN19B 343516 FL STECKER 4 8 0 5 connector 4 8mm faston CN20A 343516 FL STECKER...

Страница 25: ...0nF C0213 335787 KO KER 15 0PF 100V 2 cap ceramic 15pF C0214 329021 KO KER 0 10MF 100V 20 cap ceramic 100nF C0215 329021 KO KER 0 10MF 100V 20 cap ceramic 100nF C0216 304349 KO EL 2 200MF 50V BIP cap...

Страница 26: ...79 6V8 D0101 334321 DIODZ BZX 85C 15V 1 30W diode zener BZX 85C 15V D0102 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0103 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0104 301254 DIODE 1N 4148 AXIAL diod...

Страница 27: ...N I0301 327197 IC NE 5532 P 2FACH OP IC NE 5532 N I0302 327197 IC NE 5532 P 2FACH OP IC NE 5532 N I0600 331340 IC TL 072 CP 2FACH OP IC TL 072 CP I0700 331340 IC TL 072 CP 2FACH OP IC TL 072 CP I0701...

Страница 28: ...TRANS 2N 3906 transistor 2N 3906 Q0129 335763 TRANS 2N 3904 transistor 2N 3904 Q0141 348421 TRANS 2N 3906 transistor 2N 3906 Q0142 348421 TRANS 2N 3906 transistor 2N 3906 Q0201 330264 TRANS J 111 tra...

Страница 29: ...Ohm R0040 301674 WI SCH 10 00 OHM 2 00W 5 resistor 10 Ohm 2watt R0043 301674 WI SCH 10 00 OHM 2 00W 5 resistor 10 Ohm 2watt R0144 332306 WI SCH 3 30 KOHM 2 00W 5 resistor 3 3k Ohm 2watt R0145 332306...

Страница 30: ...n C0001 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0002 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0003 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160...

Страница 31: ...58 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0005 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0006 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0007 348458...

Страница 32: ...All manuals and user guides at all guides com...

Отзывы: