20
en | Technical data for EN54-24, Type B installations
EVID Surface Mount S Series - X Models
2022-03 | 07 | F.01U.345.358
Installation Manual
Electro-Voice
7
Technical data for EN54-24, Type B installations
Data measured and expressed as per EN54-24 requirements.
20
50
100
1000
10000
20000
3.16
10
100
316
40
50
60
70
80
Impeda
nce (Oh
ms)
Sens
itiv
ity
(dB)
Frequency (Hz)
Frequency Response, 1W / 4m, full-space
Impedance (8
mode)
Figure 7.1:
EVID-S frequency response and impedance 1 watt/4 meters/on axis
Frequency
Reproducibility
Horizontal Coverage
Vertical Coverage
(HZ)
dB/SPL
Degrees
Degrees
500
59.3
360
360
630
61.3
800
62.6
1000
62.3
160
145
1250
62.8
1600
63.0
2000
63.4
115
100
2500
63.0
3150
62.5
4000
63.2
80
35
Table 7.5:
Reproducibility and coverage angles measured full-space at 4 meters Signal at 1 watt of 1/3
octave band filtered pink noise.
Technical data EN54
Sensitivity per EN54-24
standard (SPL 1 W/4 m):
74 dB
Max measured SPL per
EN54-24 standard:
60 watt Transformer coupled @ 4 meters: 92 dB
75 watt Direct coupled @ 4 meters: 92 dB
Impedance:
Direct Coupled: 8 Ω
70V Transformer Coupled: 60 watt/68 Ω, 30 watt/135 Ω,
15 watt/250 Ω, 8 watt/446 Ω
100V Transformer Coupled: 60 watt/135 Ω, 30 watt/250 Ω,
16 watt/446 Ω