Diagnostics/Troubleshooting
4-5
Instruction Manual
Test Outputs
Intro
F
IGURE
4.3
Test Outputs
Current Command (ICMD)
This output is the command current signal
to the power amplifier. The scaling of this
signal is approximately
±
3.5 volts =
±
30
amps. This output should be used for trou-
bleshooting purposes only.
Motor Current Output (MCO)
The motor current output is an analog volt-
age which is proportional to the motor cur-
rent. The scaling of this signal is
approximately
±
1.75 volts =
±
30 amps.
This output should be used for trouble-
shooting purposes only.
Note: The scaling of this output is differ-
ent than the MCOs at P2 pins 3 and 7.
Motor Velocity Output (MVO)
The motor velocity output signal is an ana-
log voltage signal which is proportional to
the actual instantaneous motor speed. In
the standard amplifier-motor connection,
this voltage is positive for CW rotation of
the motor as viewed from the shaft end of
the motor and negative for CCW rotation.
This signal is identical to the MVO output
on P2 pin 8. (See “Motor Current Output
(MCO 0-10V)” on page 2-15.)
Содержание MAX-430
Страница 33: ...Applying Power for the First Time 3 5 Instruction Manual Intro FIGURE 3 1 System Response to a Step VCS Input ...
Страница 36: ...3 8 Applying Power for the First Time P N 0013 1025 001 Rev F ...
Страница 42: ...4 6 Diagnostics Troubleshooting P N 0013 1025 001 Rev F ...
Страница 50: ...6 6 Component Ordering Information P N 0013 1025 001 Rev F ...
Страница 52: ...7 2 Reference Drawings P N 0013 1025 001 Rev F Intro FIGURE 7 2 Simplified Circuit Diagram ...
Страница 54: ...A 2 Differences from the MAX 400 P N 0013 1025 001 Rev F ...
Страница 58: ...Help 4 Documentation Improvement Form P N 0013 1025 001 Rev F Second Fold Tape First Fold ...