2-4
Installation
P/N 0013-1025-001 Rev F
AC and DC Power Connections
AC input power to the MAX-430 must be supplied by an isolation transformer with an output
of 20-85 VAC. Refer to “Transformer Sizing” on page 2-3. Alternatively the MAX-430 may be
supplied with 30-120 VDC.
The grounding connection for AC and DC power, chassis and motor must be connected as shown
in the following wiring diagrams.
Intro
!
CAUTION
All TB1 terminals must be tightened to 9 lb-in. All wiring must be a minimum of
60
°
C insulation rating.
Intro
F
IGURE
2.2
115 VAC Input Power/Motor Wiring