23
INSTALLATION OF THE OUTDOOR UNIT
•
Try to move the product to the installation location in its original packaging.
•
As the gravity centre of the unit is not at the installation centre, special caution should be
taken when using hoisting cables to lift it up
•
During transport, the outdoor unit must not be tilted to over 45 degrees (also do not store
the unit horizontally.
•
Use expansion bolts to fix the mounting supports on the wall.
•
Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level.
•
If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as
to resist earthquake or strong wind.
Model
Pipes
Electrical cable specs
Outdoor power
supply line(quantity,
diameter, length)
Indoor power
supply line
(quantity,
diameter, length)
Indoor/outdoor
signal line
(quantity,
diameter, length)
eiQ-FC18K
(Φ6.35×0.7+Φ12.7×0.75)×5m
3×2.5mm2
/
4×2.5mm2x6.3m
eiQ-FC24K
(Φ9.52×0.75+Φ15.88×0.8)×5m
3×2.5mm2
/
4×2.5mm2x6.3m
eiQ-FC36K
(Φ9.52×0.75+Φ15.88×0.8)×5m
3×4mm2
/
4×2.5mm2x6.3m
DIMENSIONS FOR PARALLEL UNITS INSTALLATIONS
300mm(1')min