41
EM-TL01-J
OWNER’S MANUAL
2014
Green LED Codes
LED code
Explanation
Solution(s)
Green Off
No
power
or
not
operating
1.
Check if all wires are correct.
2.
Check fuse and power supply.
Green On
Normal operation
That’s great! You got the solution
Green and Red LED
Keep on
1.
Software is upgrading.
2.
Supply voltage too low or battery too high.
3.
The controller is damaged. Please contact Kelly for
warrantee.
Red LED Codes
LED code
Explanation
Solution(s)
1, 2
● ●●
Over voltage error
1.
Battery voltage is higher than max operating of the controller.
Please check the battery voltage configuration.
2.
Over voltage at regeneration. Controller will cut back or stop
regeneration.
3.
Please note there could be 2% error with overvoltage setting.
1, 3
● ●●●
Low voltage error
1.
The controller will attempt to clear the fault code automatically
after 5 second if battery voltage returns to normal.
2.
Check the battery voltage.
3.
Charge battery if necessary.
1, 4
● ●●●●
Over temperature
warning
1.
The controller temperature is over 90°C. The controller will cut
back current in the case. Stop or reduce output current to ensure
the motor temperature fall.
2, 1
●● ●
Motor fails to start
1.
Motor hasn’t reached 25 electrical RPM after 2 second from
starting. Most likely the hall or phase wiring problem.
2, 2
●● ●●
Internal voltage fault
1.
Check if the B+ and PWR voltage are correct, refer to B- or RTN.
Could be the battery voltage low.
2.
Please check load on 5V supply and the wire are correct.
3.
The controller is damaged. Please contact Kelly for warrantee.
2, 3
●● ●●●
Over temperature
1.
The controller is over 100°C. Controller stops driving in the case.
2.
Stop driving and wait for temperature fall. The controller will
restart if temperature drops below 80°C
2, 4
●● ●●●●
Throttle error at
power up
1.
The throttle signal is higher than configured dead zone at power-
on.
2.
The fault will disappear if restarts or releases throttle.
3.
Configure throttle model as “HALL Active” throttle if you use that
throttle model.
3, 1
●●● ●
Frequent reset
1.
The controller will stop driving when detects too many resets.
2.
Mostly because of B- or return wiring. Use the heavier and cleaner
return wires.
3, 2
●●● ●●
Internal reset
May be caused by some transient fault condition like a temporary
over-current, momentarily high or low battery voltage.
This can happen during normal operation
3, 3
●●● ●●●
Hall throttle short or
open circuit
1.
Check whether the throttle is short or open circuit
2.
When the throttle is normal / repaired, a restart will clear error.
3, 4
●●● ●●●●
The throttle works
on change (or try to
Controller won’t allow a motor direction change unless the throttle or
speed at zero. Fault clear when throttle is released.
Содержание EMTL01-J
Страница 1: ...EM TL01 J OWNER S MANUAL 2014 1 OWNER S MANUAL...
Страница 44: ...EM TL01 J OWNER S MANUAL 2014 44 25 ELECTRICAL WIRING SCHEMA OF HOMOLOGATED MOTORCYCLE...
Страница 45: ...45 EM TL01 J OWNER S MANUAL 2014 26 SCHEMA HOMOLOGATED ELECTRIC WIRING...
Страница 46: ...46 EM TL01 J OWNER S MANUAL 2014 27 MAIN ELECTRICAL WIRING...