In this mode the controller will only heat during a timed-on period and when receiving sufficient flow.
If no or insufficient flow is being received no heating will take place. When in a timed off period no heating
will take place.
7.4 Priority of Heating Mode
To activate the
‘Priority of Heating’
mode touch the
‘MODE’
button key until the
‘PRIORITY’
symbol is
displayed, the message
‘FLOW STABILISING’
will be displayed, after two minutes the display will change
to show
‘SAMPLING’
and after a further two minutes the display will change back to
‘PRIORITY’
.
Once the
‘Priority of Heating’
feature has been enabled the controller will take a water temperature
sample every hour and the message
‘SAMPLING’
will be displayed.
If the pool water temperature is below the required temperature, the controller will send a signal to the
heating device to come on until the required temperature is reached. When the required temperature is
reached the controller will switch the heating appliance off, followed by the filtration pump.
‘Pump Delay’
will be displayed for one hour, then a new water temperature sample will be taken, if the sampled water is
at or above the required temperature no heating will take place and the controller will switch the circulation
pump off (pump delay will be displayed), then one hour later take a new temperature sample.
The sequence will continue to repeat until
‘Priority of Heating’
is switched off.