background image

TECHNICAL DESCRIPTION

The water heater is intended for use only for domestic purposes in 
the  household  and  is  used  to  heat  water  from  common  water 
supply network, which composition and features comply with the 
specified values in water quality legislation, such as its chlorides 
composition  should  be  less  than  250  mg/l  and  its  electric 
conductivity should be more than 100 µS/cm, while its pH within 
the limits of 6.5-8 for the water heaters with enameled water tanks, 
and electric conductivity less than 200 µS/cm for the water heaters 
with chrome-nickel steel water tanks.

W

ater heaters are working with contained therein under pressure 

water. 

W

ater heaters are equipped with combined return valve, 

which prevents runtime water pressure to exceed exposure limits. 

W

ater heaters are manufactured with corrosion protection of the 

water  container  -  steel  with  durable  enamel  coating  and  an 
additional  cathodic  protection  of  anodes  with  special  alloy.  In 
production  are  as  well  modifications  with  the  anode  status 
indicator - anode tester ( "A").

T

he  thermal  insulation  of  the  water  container  is  of  foamed 

polyurethane.

U

nder  pressure

  water  heaters

  for  mounting  over  the  sink 

are 

shown

 in Fig. 

1

, a

nd

 

those

 to be mounted under the sink - in Fig. 

2

.

T

he parameters of basic water heaters with enameled water tank 

are recorded in the table.

INSTALLATION OF THE WATER HEATER ON THE 
WALL OF THE PREMISES

T

he water heater can be installed only in normal fire safeguarded 

premises and where temperature cannot fall under 0°C. For water 
heaters  under  pressure  the  availability  of  a  siphon  on  the 
installation  for  waste  waters  or  another  system  of  the  same 
purpose is needed, as during normal usage water may leak from 
the safety valve aperture. At the same time the siphon will facilitate 
the water tank maintenance, prevention and servicing operations 
when water needs to be drained out of the water tank.

W

hen  choosing  a  place  of  installation  the  dimensions  of  the 

device, its security from dripping water, method of attachment and 
connection  to  water  and  electricity  installations  are  taken  into 
account.

WARNING!

 The water heater is equipped with a power cord 

with plug and can

 NOT

 be installed in a room for bathing! 

I

n the water heater packaging is placed a suspension plate (Fig. 

3

and 3 pcs. screws and dowels for concrete. With two of the dowels 
and screws fasten the hanging plate securely to the wall of the 
room.  The  location  of  the  plate  is  selected  so  as  to  provide 
sufficient space for the device and the fittings thereof, and its water 
and electrical connections. The wall must be of sound and dense 
material (such as concrete). It is unacceptable for hanging the unit 
on decorative walls or made of hollow material. Once the plate 
suspension  is  mounted,  then  the  tank  is  hung  on  it.  For  this 
purpose on the 

device rear side there are provided holes. After the 

suspension of the appliance using the third set dowel and screw fix 
the unit rigidly to the wall through the opening of the ear of its hull, 
located to the side of the cover with the management bodies - see 
Figures 1- .

2

WARNING!

  Failure  to  comply  with  these  requirements  may 

result in damage to the device, other devices and the room in 
which the appliance is installed. In these cases, such damages 
are not covered by the warranty obligations of the manufacturer 
and the seller.

CONNECTION OF THE WATER HEATER TO THE 
WATER SUPPLY 

NETWORK

C

onnecting water heaters under pressure

W

ith an arrow towards the pipe and blue color is marked the cold 

water pipe and with an arrow from the pipe and red color insert - the 
hot water pipe.

WARNING!

 IT IS MANDATORY in the cold water to the unit to 

be mounted the supplied combined return valve and to keep the 
arrow on the valve body indicating the direction of flow through 
water flow.

IT IS PROHIBITED

 to mount any valve between the combined 

valve and the water heater! It is absolutely forbidden to block 
the side hole of the combined valve!

T

he connection of the water heater under pressure 

above

 sink is 

carried out in accordance with Fig. 

4

.

T

he connection of the water heater under pressure 

under

 sink is 

carried out in accordance with Fig. 

5

.

IT

 

IS  FORBIDDEN

 

to

  install  the  combined  valve  in  the  space 

above the unit!
Where the plumbing pipes are copper or of another metal, other 
than that of the water tank, or where brass fasteners are used, 

it is 

obligatory

 

to install on the water tank inlet and outlet non-metallic 

couplings (dielectric fittings).

F

illing the water tank of the unit under pressure is carried out in the 

following sequence: open the shut-off valve in the cold water pipe; 
open the shut-off valve of the hot water mixing battery; wait until 
the water flow is strong and solid; close the tap and hot water; lift 
the lever of the combined valve and wait 30-60 seconds of the 
lateral opening of the valve to flow thick and strong jet of water; 
then relax the valve lever.

WARNING!

  If  no  water  is  coming  out  of  the  opening  of  the 

combined  valve  or  the  flow  is  weak  (during  normal  water 
pressure), this should be considered as a malfunction indicating 
that  impurities  from  the  plumbing  or  caused  by  sewage 
connections  have  blocked  the  safety  valve  of  the  combined 
valve.  IT  IS  FORBIDDEN  to  proceed  with  appliance  electric 
connection before eliminating the reason for malfunction.

I

f necessary you may make a system for draining dripping water 

from  the  combined  valve  side  hole.  The  drain  pipe  must  have 
constant  downward  slope  and  located  in  anti-freezing 
environment with extremities in the atmosphere.

WARNING!

  Failure  to  comply  with  the  requirements  for 

connection to the water supply system may cause partial filling 
up of the water tank and malfunction of the heating element, or 
when  the  combined  valve  is  not  installed  at  all  or  has  been 
improperly  installed  this  may  even  cause  destruction  of  the 
water  tank.  Such  consequences  are  not  within  the  scope  of 
manufacturer or seller warranty liabilities and shall be at the 
expense  of  the  party,  which  has  not  observed  the  present 
manual instructions.

D

raining the water from the water tank

(performed  when  possible  temperature  drop  below  0°C  in  the 
room where the water heater is, as well as before eventual repairs)

W

ater heater under pressure for mounting over sink

S

top the cold water flow to the tank by closing the cold water tap - 

pos. 

4

 of Fig. 

4

. Remove the power cord plug of the heater outlet. 

Open the hot water tap of the closes mixer in order to free the 
pressure within the unit. Disconnect the unit hot water pipe from 
the water mains in the premise. Release the combined valve lever. 

4

Содержание 72324NMP

Страница 1: ...v220609 HOUSEHOLD ELECTRIC WATER HEATERS TECHNICAL DESCRIPTION MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE WARRANTY AND WARRANTY CONDITIONS...

Страница 2: ...old water Hot water 7 10 15 7 15 1 5 2 2 0 7 0 7 285 285 285 285 285 288 288 288 288 288 340 430 520 340 520 Installation For installation above sink For installation under sink Operation principle Un...

Страница 3: ...ith water Failure to comply shall make the appliancedangerousandinsuchstateitsuseisstrictlyforbidden WARNING Whenusingtheappliancethereisariskofhotwaterscalding WARNING Do not touch the appliance and...

Страница 4: ...s and the room in which the appliance is installed In these cases such damages are not covered by the warranty obligations of the manufacturer andtheseller CONNECTION OF THE WATER HEATER TO THE WATERS...

Страница 5: ...ting and water is heating while when the light is off it indicates that the water has reached adjusted temperature andtheheaterisswitchedoff Using the knob the temperature to which it will heat the wa...

Страница 6: ...the process of using the heaternotlessthanonceeverytwoweeks aswellaseventually afterstopand startof watersupply Whenat fulltankby opening the valve does not leak or water flow is weak there is a fail...

Страница 7: ...m and pH is outside of 6 5 8 for water heaters with enameled water tanks the electrical conductivity is more than 200 S cm for water heaters with watertanksmadeofchrome nickelsteel Supplyvoltage diffe...

Страница 8: ...ELDOMINVEST Ltd 275A Vl Varnenchik blvd Varna 9009 Bulgaria Manufacturer www eldominvest com...

Отзывы: