background image

© 

2010 eldoLED. All rights reserved.

More information (datasheets, application notes, user manuals) and eldoLED’s terms and conditions are available at www.eldoled.com.

 Wiring diagram LINEARdrive 180                                                       (LIN180D1)

Ext in +

Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -

LedSync shield

TC

1

2

3

Group

Group

Group

Group

LED

LINEARdrive 180D

 -

4

12-28V / 6A Direct voltage controlled LED driver

LED groups

DMX in shield

DMX in +
DMX in -

Ext in +
Ext in -

{

12V-28V DC IN

VDC - VDC +

LedSync thru shield

LedSync thru +

LedSync thru -

R

R

W

R

B

G

LED sup

R

R

Max | Vdc+

28V | Vdc-

CAUTION: incorrect installation of the device can cause irreparable damage to the device and the connected LEDs. 
Therefore, the device must only be connected and installed by a qualified electrician. All applicable regulations, 
legislation and building codes must be observed!

12V - 28V DC IN 

To connect the driver/controller to a DC power supply (PSU), 
connect the PSU’s positive voltage supply wire to the VDC+ 
connector and the PSU’s negative voltage supply wire to the 
VDC- connector.

EXT in (optional)

Connect an external control device (0...10V control device, 
10k

 potentiometer or show selection switch) to the driver/

controller by connecting the device’s positive lead to the EXT 
in+ connector and its negative lead to the EXT in- connector. 
Configure the driver/controller for use with an external control 
device over the 3-button user interface.

DMX in/LedSync thru (optional)

Use these connectors when the driver/controller is used in a 
DMX network.
For data input, connect the network cable’s data+, data- and 
shielding wire (the orange/white, orange and brown wire in a 
CAT5 cable) to the DMX in+, DMX in- and DMX in shield con-
nector respectively.
For data output, connect the network cable’s data+, data- and 
shielding wire (the orange/white, orange and brown wire in a 
CAT5 cable) to the LedSync thru+, LedSync thru- and 
LedSync shield connector respectively.

LED groups

Indicates the location of the connectors to which you 
can connect your LED groups. R(ed) represents channel 1, 
G(reen) represents channel 2, B(lue) represents channel 3 
and W(hite) represents channel 4. The default group color al-
location can be changed over the 3-button user interface.

Отзывы: