MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
31.1.2. EKB3 - LED Keypad
Main features:
• Alarm system arming and disarming (see
12.4. EKB3 Keypad and User Code
).
• Arming and disarming in Stay mode (see
15. STAY MODE
).
• System parameter configuration (see
5. CONFIGURATION METHODS
).
• PGM output control (see
18.4. Turning PGM Outputs ON and OFF
).
• Visual indication by LED indicators (see
32.1.2.1. LED Functionality
).
• Audio indication by built-in buzzer.
• Keypad partition switch (see
23.3. Keypad Partition and Keypad Partition Switch
).
For more details on technical specifications and installation, please refer to the latest user manual of the device located at www.eldes.lt/
download
31.1.2.1. LED Functionality
ARMED
Steady ON - alarm system is armed / exit delay in progress; flashing - Configuration mode activated
READY
Steady ON - system is ready – no violated zones and tampers
SYSTEM
Steady ON - system faults; flashing - violated high-numbered zone (Z13-Z44)
BYPS
Steady ON - zone bypass mode
1-12
Steady ON - violated zone Z1... Z12
31.1.2.2. Keys Functionality
1
2
3
4
5
6
7
ARMED
READY
SYSTEM
BYPS
A
B
1
2
3
4
5
6
7
8
9
10
11
12
8
9
*
0
#
STAY
BYPS
INST
CODE
FRONT SIDE
44
[BYPS]
Bypass violated zone
[CODE]
System fault list / violated high-numbered
zone indication / violated tamper indication
[*]
1st character for Configuration mode activati-
on/deactivation command / clear typed in cha-
racters / keypad partition switch (if enabled)
[#]
Confirm (enter) command
[0] ... [9]
Command typing
[STAY]
Manual system arming in Stay mode
[INST]
N/A
31.2. 1-Wire Interface
1-Wire interface is used for the system to communicate with an iButton key reader and a temperature sensor. 1-Wire interface COM and DATA
terminals are ground and data respectively. When connecting single or multiple temperature sensors, the +5V terminal must be used along.
For more details on 1-Wire device wiring, please refer to
2.3.4. iButton Key Reader and Buzzer
and
2.3.5. Temperature Sensor and
iBut ton Key Reader
.
Main iButton features:
• Up to 5 iButton keys per alarm system unit ESIM264;
• Communication via 1-Wire interface.
31.3. Modules Interface
The system might be equipped with modules interface slots thus enabling to use one of the following devices at a time:
• EPGM8 - hardwired PGM output expansion module (for more details on technical specifications and installation, please refer to the
latest user manual of the device located at www.eldes.lt/download)
• EA1 - audio output module (see
31.2.1. EA1 - Audio Output Module
)
• EA2 - audio output module with amplifier (see
31.2.2. EA2 - Audio Output Module with Amplifier
)
31.3.1. EA1 – Audio Output Module
EA1 audio output module enables a duplex audio connection for ESIM264 alarm system.
Main EA1 features:
• Two-way voice conversation during a phone call;
• Possibility to connect headphones or desktop speakers.
31.3.1.1. Technical Specifications
• 3,5 mm female jack
• Dimensions: 41x40x24mm (1.61x1.57x0.95in)
31.3.1.2. Installation
1. Disconnect ESIM264 alarm system mains power and backup battery.
2. Insert EA1 pins into appropriate ESIM264 alarm system slots.
ESIM264
EA1
45
3. Connect headphones or desktop speakers to EA1 3,5 mm female jack.
EA1
46
4. Power up ESIM264 alarm system.
5. EA1 is ready for use with ESIM264 alarm system.
Содержание ESIM264