29. INDICATION OF SYSTEM FAULTS
The system comes equipped with self-diagnostic feature allowing to indicate the presence of any system fault by the keypad.
EKB2
Message
TBL
displayed in the home screen view indicates presence of system faults. In order to find out more on the particu-
lar system problem, please open menu section
TROUBLES
. The description on each system problem is indicated in the table
below.
Menu path:
OK
→
TROUBLES
Name
Description
VIOLATED TAMPER
One or more tampers are violated
BATTERY FAILED
Backup battery requires replacement - backup
battery resistance is 2Ω or higher
MAIN PWR FAILURE
Mains power supply is lost
DATE/TIME NOT SET
Date/time not set
GSM ERROR
GSM connection is lost
EKB3
Yellow LED
SYSTEM
indicates system faults.
SYSTEM
LED indications are mentioned in the table below.
SYSTEM LED
Description
Steady ON
One or more tampers are violated; other system faults (see below)
Flashing
One or more high-numbered zones are violated
In order to find out more on the particular system fault, please enter command A provided below. After this procedure the system
will activate red zone LEDs for 15 seconds. The description on each LED indication is mentioned in the table below.
Zone LED
Description
1
One or more tampers are violated
2
Backup battery requires replacement - backup battery resistance is 2Ω or higher
3
Mains power supply is lost
4
Date/time not set.
5
One or more high-numbered zones (Z13-Z44) are violated
6
GSM connection is lost
In order to find out which particular high-numbered zone is violated please , enter command B.
In order to find out which particular tamper is violated please , enter command C.
A. System fault indication - enter command:
[CODE#]
B. Violated high-numbered zone indication – enter command:
[CODE1]
C. Violated tamper indication – enter command:
[CODE2]
The number of violated high-numbered zone or tamper can be calculated using the table below according to the formula: number
from zone LED section B + number from zone LED section A.
Example:
LED #3 from section A is flashing and LED #8 from section B is illuminated continuously. According to the table below
LED #8 is equal to number 18, therefore 18 + 3 = 21.
Result
: Violated high-numbered zone or tamper number is 21.
Zone LED section - A (flashing) Zone LED section - B (steady ON)
Zone LED 1 = 1
Zone LED 7 = 12
Zone LED 2 = 2
Zone LED 8 = 18
Zone LED 3 = 3
Zone LED 9 = 24
Zone LED 4 = 4
Zone LED 10 = 30
Zone LED 5 = 5
Zone LED 11 = 36
Zone LED 6 = 6
Zone LED 12 = 42
30. MONITORING STATION
The system can be configured to report events to the monitoring station by transmitting data messages to the monitoring station. The
system connects to the monitoring station when the MS (Monitoring Station) mode is enabled.
When using the MS mode, the data messages transmitted to the monitoring station (see
30.1. Data Messages - Events
) will gain the
highest priority for the delivery, therefore based on the communication method (see
30.2. Communication
), a constant and stable con-
nection with the monitoring station must be ensured. In case of connection failure, the system will attempt to restore the connection
and if the monitoring is unavailable for a lengthy period of time, the system might consume a large amount of voice calls/data resulting in
additional charges applied by the GSM operator according to the cell phone service plan.
Enable MS mode
SMS
SMS text message content:
ssss_SCNSET:ON
Value:
ssss
– 4-digit SMS password.
Example:
1111_SCNSET:ON
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
MS MODE
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password
EKB3
Enter parameter 23 and parameter status value:
23 1 #
Example:
231#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable MS mode
SMS
SMS text message content:
ssss_SCNSET:OFF
Value:
ssss
– 4-digit SMS password.
Example:
1111_SCNSET:OFF
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
MS MODE
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password
EKB3
Enter parameter 23 and parameter status value:
23 0 #
Example:
230#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Account is a 4-digit number (By default – 9999) required to identify the alarm system unit by the monitoring station.
Set account
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
ACCOUNT
→
OK
→
cccc
→
OK
Value:
aaaa
– 4-digit administrator password; cccc – 4-digit account number.
EKB3
Enter parameter 27 and account number:
27 cccc #
Value:
cccc
– 4-digit account number.
Example:
278853#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.