GB
Power Plug Radio Call Detector RCP09
Models
Scope of Delivery
Safety Advice
Concept of Operations
The device may only be operated indoors as
acoustic signaller for notifications of alarm
signals and indicates the battery condition of
the tranmitters (evaluation undervoltage
telegram).
The outlet can only be used for mains voltage
consumers.
The manufacturer will not be liable for damage
caused by improper or inappropriate use
.
Intended Use
Function
Function/Chapter
Operation
[press the button]
LED-view RCP09
Further actions
Teaching in the
call transmitter
1. button R (>1,6 s)
2.
call transmitter
R
button
button
button
flashes
button
light up
R
R
4 s
after 20 s operation mode
teaching in furthertransmitter
cancel
Teaching in
acknowledgement
transmitter
1.
Q (>1,6 s)
2.
acknowl. transmitter
Q
button
button
button
button
flashes
button
light up
Q
Q
4 s
after 20 s operation mode
teaching in furthertransmitter
cancel
Selecting the
melody
button
button
button
R
R
R
1. Westminster
2. March
3. Ringing Bell
default settings
Setting the
volume/
flashlight
button
button
button
button
button
Q
Q
Q
Q
Q
1.
2.
3.
4. Quiet
5. Loud
Quiet and flashing light
Loud and flashing light
Muted
(only flashing light)
default settings
Acknowledging
a call
button
button
acknowl. transmitter
R,
Q or
Deleting
individual
transmitters
1.
R
+
Q
(>1,6 s)
2. call- or acknowledgement
transmitter
R or
Q
button
button
button
button
button
flash
button R and Q light up
R and Q
4 s
after 20 s operation mode
cancel
deleting further
transmitters
Reset to Default
Settings
(RESET)
1.
R
+
Q (>1,6 s)
2.
R
+
Q (>1,6 s)
button R or button Q
button
button
button
button
button R and Q flash
button R and Q light up 4 s
after 20 s operation mode
cancel
default settings
Wall outlet
Loudspeaker
Button Q
Button R
Flashlight
RCP09 5001-12
868.30 MHz
GB
RCP09 5001-14
868.30 MHz
F/B
E
E
Power plug call signaller RCP09, operating
instruction
Please read these instructions
carefully before using the device!
We do not accept any liability for personal
injury or damage to property caused by
incorrect handling or non-observance of the
safety instructions!
Observe the valid laws and regulations as
well as the manufacturer's instructions for the
devices to be operated!
Frequency:
868.30 MHz
Modulation:
FSK
:
230 V AC / 50 Hz
Current consumtion: max. 7 mA
Power consumption: approx. 0.3 W (stand by
: IP 20
:
-20°C to +35°C
:
60%
:
122 x 50 x 75 mm
:
190 g
Operating voltage
Loudness:
Distance 30 cm:
quiet: 75 dB, loud: 82 dB
Degree
of
protection
Operating
temperature
Max. relative air
humidity
Mains output
Power plug
(non switchable)
Max. contact load:
GB
13 A / 230 V AC
F/B (PL)
16 A / 230 V AC
Dimensions
(HxWxD):
Weight
Technical Details
Attention!
Observe the admissible supply
voltage and the maximum contact load of the
wall outlet (
see „Technical Details“
)!
Do not plug one Call Detector into another.
The Call Detector is only de-energized when
it is disconnected from the mains supply.
The Call Detector must be easily accessible.
Have malfunctioning devices checked by the
manufacturers!
Do not open the appliance's casing!
Do not make any unauthorized alterations or
modifications to the unit!
The call signaller RCP09 serves for acoustic and
optic signalling of care requests. The call is
triggered by a handheld radio transmitter.
Þ
ringing tone
Þ
The outlet of the call signaller can be used as an
outlet for any electric devices.
The melodies "Westminster", "March" or "Ring
tone" can be selected. By default, the call
signaller plays the "Westminster" melody.
Cyclic call signalling:
1. 1.5 min ringing tone
3 min break,
2. 1.5 min
3 min break,
3. 1.5 min
10 min break,
4. 1.5 min
timeout.
The optic signal by the flashlight (if activated)
continues until the call is acknowledged. The call
can be acknowledged directly on the call
signaller or with an acknowledgement transmit-
ter.
It is also possible to evaluate an undervoltage
telegram indicating a low battery status of the
radio transmitters RT26, RT27 and RT28.
The weak battery status is indicated by the
alternate blinking of the buttons and can be
deactivated by pressing one of the two buttons.
ringing tone
Þ
ringing tone
Þ
Altogether 64 send codes can be programmed in
the call signaller (32 request codes and 32
acknowledgement codes).
Start-up
1. Plug the call detector into a
properly functioning earthed
outlet. You will hear a brief
acknowledgement signal.
2. Teach the coding of the call transmitter into
the call detector (see section "Teaching in the
call transmitter").
3. Teach the coding of the acknowledgement
transmitter into the call detector (see section
"Teaching in the acknowledgement trans-
mitter").
4. Select a new melody if desired.
5. Change the volume/flashlight combination if
desired.
Attention! Ensure an interference-free wireless
connection. Do not install the device in a
distribution box, metal housings or close to large
metal objects.
R
Q
GB
F/B (PL)
Max. Contact load of sockets:
13 A
16 A