TECHNICAL DATA
16/64
EN
3 .2
Technical data
FB 2 K 18 LN FB 2 K 20 LN FB 2 K 26 LN FB 2 K 35 LN
Burner output factory setting
(1)
16,0 kW
18,6 kW
24,0 kW
31,7 kW
13.760 kcal/h
16.000 kcal/h
20.640 kcal/h
27.260 kcal/h
Oil throughput factory setting
(1)
1,3 kg/h
1,5 kg/h
2,0 kg/h
2,6 kg/h
Fuel oil
(2)
Kerosene , visc 1÷2,5 mm2/s at 20°C (Hi=11,97 kWh/kg)
NOx emissions
< 120 mg/kWh
(according to European Commission Regulation No 813/2013
and to pr EN267/2016 Class 4)
Control box
EBR-M1 20-30
Flame sensor
Photoelectric controller (PEC)
Ignition transformer
Fida 2P 26 kV pp-35 mA rms
Fuel-oil pump
Danfoss BFP special
Pump coil
BFP T85
Electric motor
EBR 90 W, 2800 rpm
90 watt
Capacitor
Inco 4 μF , TEKNO 45T (T = top series)
Electrical supply
1 / 230 / 50 Ph / V / Hz
Power consumption (operation) (+/- 5W)
188 W
190 W
185 W
175 W
Protection level
IP40
Sound pressure level
65 dB(A)
Ambient temperature for storage
-20°C ... +70°C
Temperature for use
-10°C ... +60°C
(1)
Reference conditions: Ambient temperature 20 °C – Barometric pressure 1013 mbar – Altitude 0 m. a.s.l.
WARNING
(2)
The burner is suitable for kerosene with bio content up to 10%. It is a minimum requirement
that the fuel blend (up to 10% Bio) is obtained with kerosene in accordance with the relevant
standards and regional regulations.
In case of Bio oil content higher that 10% please contact the manufacturer.
WARNING
Содержание Firebird FB 2 K LN