background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

                    

REV. 1.0 

 01/20

 

 

Содержание Nikken E346+

Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL REV 1 0 01 20...

Страница 2: ...2...

Страница 3: ...THE SPINDLE 19 6 5 1 REPLACING ROTATING SPINDLE 19 6 5 2 MANUAL SPINDLE BRAKE 19 7 COLLIMATION 20 7 1 INTRODUCTION 20 7 2 IMAGE FOCUSING 20 8 MACHINE ORIGINS 23 8 1 NC MACHINE ORIGINS 23 9 INSTALLING...

Страница 4: ...p 1 class A EN61000 3 2 2014 EN61000 3 3 2013 EN61000 4 2 2009 EN61000 4 3 2006 A1 2008 A2 2010 EN61000 4 4 2012 EN61000 4 5 2006 EN61000 4 6 2009 EN61000 4 11 2004 2014 35 UE Low Voltage Directive LV...

Страница 5: ...al is to allow the operator of the presetter E346 V to become acquainted with the machine operating directions routine and non routine maintenance the proper operating procedures and to show all the r...

Страница 6: ...K POLYGONAL TAPER etc interchangeable rotating spindle holder to be specified max run out error 4 m Double vault arc prismatic slideways N 2 X axis slideways N 1 Z axis slideway Double re circulating...

Страница 7: ...CUUM locking system available in 50 40 30 versions Only E346V model HSK FORM A C E Interchangeable spindle holder available in 100 80 63 50 40 32 versions VDI Interchangeable spindle holder available...

Страница 8: ...ation and installation check that the tool presetter packaging contains the following components TOOL PRESETTER Model E346 Spindle E346V RESETTING GAUGES CONE REDUCTION ADAPTER ISO ISO other ISO ISO o...

Страница 9: ...rl is to be considered improper use The maximum weight of the tool to be measured should be no more than 30Kg Any other use is to be considered improper and potentially compromising to the operator s...

Страница 10: ...5 PREPARATION AND INSTALLATION ELBO CONTROLLI srl Preset E346 V 10 5 5 UNPACKING INSTRUCTIONS...

Страница 11: ...5 PREPARATION AND INSTALLATION ELBO CONTROLLI srl Preset E346 V 11...

Страница 12: ...or fast movement to block and unblock axis Z Rotating spindle holder brake Adjustment wheel for axis X Adjustment knob wheel for axis Z C MOS image sensor Vertical LCD Monitor Touch screen 15 Knob to...

Страница 13: ...EW k l Start button ON OFF switch Power cable for DYMO mini printer supplied with the machine DYMO mini printer power connection Ground terminal 24Vdc Power Supply connection Rotating spindle holder V...

Страница 14: ...performance is obtained in a constant temperature environment 5 7 POWER SUPPLY The power supply points are located on the back of the preset also pneumatic for E346V version E346 V Presetter is powere...

Страница 15: ...ed 5 7 1 USB RJ45 HUB In the support column of the LCD monitor there is a HUB equipped with 3 USB ports for connecting any external peripherals e g mouse keyboard DYMO mini printer 1 RJ45 port to perm...

Страница 16: ...en press the power button on the right side of the machine and wait for the software to commence For use refer to the software manual supplied with the machine ON OFF switch Start button Help on line...

Страница 17: ...The transition from rapid movement to the acute movement occurs by unlocking and locking the respective axes axis unlocked rapid movement axis blocked acute movement 6 4 1 RAPID MOVEMENT In order to r...

Страница 18: ...ective blocking wheel handles until the black bullet marker is positioned on the front part of the machine Rotate the acute movement handle of the axis to the area of interest on the screen to carry o...

Страница 19: ...holder during insertion keep it parallel with the column If you have adapters instead of rotating spindles follow the procedure below Procedure for replacing spindle adaptors Remove if present the ot...

Страница 20: ...xclusion of measurement subjectivity which makes measurements objective and repetitive In fact E346 V can analyse the cutting edge of the tool and find out its measurement points in the profile with a...

Страница 21: ...ndicator to be found with each bar Don t forget the measurement point is the one relating to the tool maximum tangency and that focusing is only used to make the search easier in fact the maximum tang...

Страница 22: ...e measured tool and approximately corresponds to 0 01 mm for tools having a radius of 20 mm while it is smaller than 0 001 mm For radii that are bigger than 80 mm Based on these considerations it is n...

Страница 23: ...the display A more efficient system is to use the same origin given by the length marked on the reset gauge for all of the machines having the same spindle intersection The electronic equipment 212S...

Страница 24: ...en installed by Elbo Controlli so it can be connected to the power supply with the feeder and to the presetter via the USB port If the printer is purchased later it requires installation through the f...

Страница 25: ...RINTER REPLACEMENT If you need to substitute the labelling machine you need to uninstall the existing one Press System on the menu bar then select Administrator and Printing Select the printer icon to...

Страница 26: ...LI srl Preset E346 V 26 To confirm press Delete If more than one Dymo LabelWriter printers is installed repeat the operation until they are all removed Press to close the windows Now you can install t...

Страница 27: ...The display panel container is made of metal sheet the polyester touchscreen to clean we recommend the use of a clean cloth moistened with suitable degreasing products avoid the use of solvents and ab...

Страница 28: ...n output voltage of 24 Vdc repeat the test with the preset connected If the voltage of 24 Vdc is present also in this case contact the assistance service PROBLEM difficulty moving the Z axis upwards C...

Страница 29: ...erials The separate waste collection of the apparatus which has reached the end of its useful life is organized and managed by the national dealer The end user who desires to get rid of the present ap...

Страница 30: ...13 ELECTRICAL DIAGRAM ELBO CONTROLLI srl Preset E346 V 13 ELECTRICAL DIAGRAM...

Страница 31: ...14 PNEUMATIC DIAGRAM ELBO CONTROLLI srl Preset E346 V 14 PNEUMATIC DIAGRAM E346V VERSION ONLY...

Страница 32: ...is manual can be modified without any prior notice No part of this manual can be reproduced in any way or means without the prior written consent of ELBO CONTROLLI s r l Via S Giorgio 21 20821 Meda MB...