background image

  Rev. 2/11/2008 

                 

   Version 1.41 

     

User Manual

 

 

           

 

Elation Professional 

6122 S Eastern Ave 

Los Angeles, Ca 90040 

www.elationlighting.com

 

Содержание Impression Professional Impres

Страница 1: ...Rev 2 11 2008 Version 1 41 User Manual Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Страница 2: ...Elation Professional 2 impression...

Страница 3: ...g and Installation 12 a Mounting Points 13 b Clamp Mounting 14 c Floor Mounting 14 d Side Mounting 15 e Securing 16 7 Understanding DMX 17 a DMX Cable Requirements 17 b DMX Terminator 19 c 3 Pin to 5...

Страница 4: ...necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this un...

Страница 5: ...he package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 Never open this fixture while in use This fixture operates with...

Страница 6: ...e blindness 5 For safe operation follow the Installation guide described in chapter three of this manual Operating the Impression without suited safety aids such as safety cables or clamps can increas...

Страница 7: ...Arm with various cooling vents 3 LCD Full Text Display and Menu with Foil Key Pad data entry 4 Base with various connectors and Camlock mounting system 5 Power On Off Switch 6 DMX Output 3 pin XLR 7...

Страница 8: ...rmined internal operating temperature the fan functions at high speeds The higher speeds provide better cooling associated with higher operating temperatures during long use When the fixture is operat...

Страница 9: ...operation Never defeat this fuse this fuse is designed to protect the electronics in the event of severer power fluctuations In the event of fuse failure always be sure to replace this fuse with an ex...

Страница 10: ...second or random strobe 90 Bright Luxeon K2 High Powered LEDs Dimmer intensity from 0 100 Electronic Power Supply 100 240v 50Hz 60Hz Control board with full LCD character display and foil keyboard Rev...

Страница 11: ...he fixture and a wall or flat surface should be at least 5 meter about 1 5ft Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always b...

Страница 12: ...this fixture is kept at least 0 5m away from any flammable materials decoration etc Always use and install a safety cable as an additional safety measure to prevent accidental damage and or injury in...

Страница 13: ...lation procedures before connecting main power Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff shou...

Страница 14: ...the safety cable rigging point integrated in the base Floor Mounting The Impression ships with a floor stand that will properly balance the fixture in an up right position For upright operation alway...

Страница 15: ...amp Mounting section on the previous page as it may damage the base The side mounting assembly was specifically designed to cope with excessive torque that occurs when the fixture is mounted on its si...

Страница 16: ...your IMPRESSION always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only...

Страница 17: ...ine does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX contro...

Страница 18: ...512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head Please refer to the diagram be...

Страница 19: ...Elation part DMX T PACK will decrease the possibilities of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtu...

Страница 20: ...xture That means changing the settings of one channel will only affect the selected fixture In the case of the Impression which is a 14 channel fixture you should set the starting DMX address of the f...

Страница 21: ...he front of the unit Press this button to activate the system menu Tap the UP button until you reach the function you wish to change When you reach the function you wish to change tap the ENTER button...

Страница 22: ...all functions to the factory values Adjust Key code xxxx Code protection for the calibration menu for use by authorized technicians only Pan Offset Calibration for Pan Offset Tilt Offset Calibration...

Страница 23: ...e for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for Color Wheel Tilt Instantaneous value for Tilt movement Live time Indicates the overal...

Страница 24: ...nal power source that should last about five years Universal DMX Control This function allows you to use a universal DMX 512 controller such as the Elation Show Designer 2 or Elation Show Designer 3 t...

Страница 25: ...nnel Function Time and Value DMX HEX 1 Pan Coarse 0 660 Min 3 2 s 0 255 00 FF 0 100 2 Pan Fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt Coarse 0 300 Min 1 5 s 0 255 00 FF 0 100 4 Tilt Fin...

Страница 26: ...S 2 3 BPS 1 43 s 0 43 s 112 127 70 7F 44 49 5 Color1 Chaser C C 2 Slow fast 0 7 BPS 2 0 BPS 1 43 s 0 5 s 128 143 80 8F 50 56 5 Fan min as long as temp 60 C 224 229 E0 E5 88 89 5 RESET Normal Mode 250...

Страница 27: ...cial DMX channel If the Special channel is set to a value between DMX 0 15 the White Mode is not used and the RGB goes for the maximum light output If the Special channel is set to a value between DMX...

Страница 28: ...22 24 5 Color 08 Dark Blue 64 71 40 47 25 27 5 Color 09 Pink 72 79 48 4F 28 30 5 Color 10 Lime Green 80 87 50 57 31 34 5 Color 11 Light Blue 88 95 58 5F 35 37 5 Color 12 Red 96 103 60 67 38 40 5 Colo...

Страница 29: ...255 00 FF 0 100 7 Green Coarse Color Mix Green 0 100 0 255 00 FF 0 100 8 Green Fine Color Mix Green High 0 100 0 255 00 FF 0 100 9 Blue Coarse Color Mix Blue 0 100 0 255 00 FF 0 100 10 Blue Fine Colo...

Страница 30: ...rotate freely 4 Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on installation a...

Страница 31: ...ion Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or rem...

Страница 32: ...rchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to...

Страница 33: ...Elation Professional 33 impression 13 DIMENSIONAL DRAWINGS...

Страница 34: ...optical carrier with 10 light distribution angle 25 optional Scattering light aperture Shutter Dimmer 8 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effect...

Страница 35: ...Elation Professional 35 impression...

Страница 36: ...Elation Professional 36 impression Elation Professional 6122 S Easter Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Отзывы: