background image

 

 

 

 

Rev. 12/08/2010 – visage 

 

  Version 1.0 

 

 

 

 

 

 

 

 

 

 

 

 

ELAR PAR 72 UV 

 

 
 

Elation Professional™ 

6122 S. Eastern Ave. 

Los Angeles, Ca 90040 

www.elationlighting.com

 

Содержание ELAR PAR 72 UV

Страница 1: ...Rev 12 08 2010 visage Version 1 0 ELAR PAR 72 UV Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Страница 2: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 1 www ElationLighting com...

Страница 3: ...9 6 Mounting and Installation 12 7 Understanding DMX 15 a DMX Cables 15 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 17 d Fixture DMX Addressing 17 8 Display Indicators 19 9 Display Menu 20 10 DMX...

Страница 4: ...y to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you should find th...

Страница 5: ...nder warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the pro...

Страница 6: ...pter six of this manual Operating the ELAR PAR 72 UV without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Qualified and certified personn...

Страница 7: ...tugging the wire portion of the cord 14 Please safe keeping the waterproof socket packed in the attached bag Cover the power cable and signal cable by the socket when the cable leave unused 15 Please...

Страница 8: ...Field Angle 45 Lens USITT DMX 512 Complaint Preprogrammed colored macros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function...

Страница 9: ...treme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft See page 12 Always install the fixture with an appropriately ra...

Страница 10: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 9 www ElationLighting com 5 FIXTURE OVERVIEW...

Страница 11: ...in the DMX chain To maintain the integrity of the IP rating only use proper Elation IP rated DMX cables 5 MENU Button This button is used to access the fixtures menu functions 6 Up Button The up butto...

Страница 12: ...connectors to maintain the IP rating 11 DMX In Lead This lead is the main DMX input lead When the unit is the first in a chain or the only fixture to be used with a DMX controller be sure to use the D...

Страница 13: ...g removing or servicing the fixture Refer to regulations BGV C1 formerly VBG 70 and DIN VDE0711 217 for proper installation in Europe To ensure proper installation only qualified staff should attempt...

Страница 14: ...ounting always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure See the image below Clamp Mounting The ELAR PAR 72 UV p...

Страница 15: ...safety measure be sure to attach at least one properly rated safety cable to the fixture See illustrations below Securing the ELAR PAR 72 UV Always be sure to secure your fixture with a safety cable...

Страница 16: ...e connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the...

Страница 17: ...multiple moving heads together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out...

Страница 18: ...g a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control info...

Страница 19: ...whether a DMX data signal is being received or not If a DMX data signal is being received the display will show A XXX XXX representing the actual DMX address If the fixture is not receiving a DMX sign...

Страница 20: ...ndicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicator...

Страница 21: ...SLAV ON OFF Set as Slave ADDR RDMX ON OFF Change address via DMX RUN AUTO ALON MAST Run Auto program VALU D XX D 00 DXXX Display DMX value FLIP ON OFF Flip display D ON ON OFF Delay shutting off LED d...

Страница 22: ...e setting for Master Slave Operation With this function you can define the device as slave for operation in Master Slave mode Each slave setting will have a different function for a dynamic lightshow...

Страница 23: ...excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will remain on before it turns off This function is disabled as default LO...

Страница 24: ...manual setting that are made in the MANL menu section If this function is not activated all manual settings will be lost once the fixture is tuned off VER Software Version This function will display...

Страница 25: ...total amount of steps in the built in program This setting can range between 1 and 48 steps 9 5 2 REC Auto save function 9 5 3 SCXX This function allows the user to edit the scenes in the user define...

Страница 26: ...is scene needs 3 0 seconds to run Note XX is always 0 2 seconds not one second 11 Adjust the time needed by tapping the UP button 12 Press ENTER to save the settings for the scene you are editing the...

Страница 27: ...com 9 Adjust the Step time as described above 10 Call up the second scene in your controller now 11 Repeat steps 5 11 until all desired scenes are downloaded 12 Press MODE ESC to exit The number of s...

Страница 28: ...ile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addr...

Страница 29: ...1 to a value of 7 set channel 2 to a value of 7 and use channel 3 to set your address to 57 by selecting a channel value of 57 Example 2 If you want to set the starting address to 420 set channel 1 to...

Страница 30: ...is receiving a DMX signal Please note that this will override all manual settings This unit will keep and retain the last DMX command in the event of DMX signal failure To reset the fixture you must...

Страница 31: ...o different DMX modes DMX channel functions values 2 DMX channels Channel Value Function 2CH Shutter strobe 0 31 Blackout LEDs Off 32 63 Open LEDs On 64 95 Strobe effect slow to fast 96 127 Open LEDs...

Страница 32: ...ogram 1 48 then creating the scenes Keep in mind that although you can create a total of 48 unique scenes the program will only playback the total amount of steps that have been assigned to the progra...

Страница 33: ...down buttons to adjust the DMX channel value 5 Press ENTER to adjust the value to any remaining channels 6 Repeat steps 3 5 until you finish setting all the DMX values for all channels of this scene...

Страница 34: ...Mode and tap the Enter button In the next screen select Run and tap Enter In the next screen toggle to Auto and tap enter There are now two selections Master and Alone Select Master when running mult...

Страница 35: ...over is held in place by two turn locking fasteners To remove the cover 1 Turn the locking fasteners in a counter clockwise direction 2 Once the fasteners are loose lift the cover straight up to expos...

Страница 36: ...not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled...

Страница 37: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number ha...

Страница 38: ...ding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or f...

Страница 39: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 38 www ElationLighting com 16 PHOTOMETRIC DATA...

Страница 40: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 39 www ElationLighting com 17 DIMENSIONAL DRAWINGS...

Страница 41: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 40 www ElationLighting com 18 CIRCUIT SCHEMATIC...

Страница 42: ...ls DMX Drive Standard DMX 512 3 pole IP Rated Locking Connector Pin 3 Pin 2 Ground Pin 1 Color Mixing RGBW Color Additive Mixing Beam Angle 20 Beam Angle 60 Field Angle 45 Lens Dimmer Continuous Dimmi...

Страница 43: ...ELAR PAR 72 UV Elation Professional Los Angeles Ca 42 www ElationLighting com...

Страница 44: ...Rev 12 08 2010 visage Version 1 0 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighting com...

Отзывы: