Elation Design Spot LED Скачать руководство пользователя страница 1

  Rev. 3/04/2010 – visage   

                 

                Version 1.0     

   

 

   

 

 

 

 

 

 

 

Design Spot LED 

 

Elation Professional 

6122 S Eastern Ave 

Los Angeles, Ca 90040 

www.elationlighting.com

 

Содержание Design Spot LED

Страница 1: ...Rev 3 04 2010 visage Version 1 0 Design Spot LED Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com...

Страница 2: ...Design Spot LED Elation Professional 2 Design Spot LED...

Страница 3: ...ounting Points 11 b Securing 12 6 Understanding DMX 13 a DMX Cable Requirements 13 b DMX Terminator 15 c 3 Pin to 5 Pin Conversion 15 d DMX Addressing 15 7 Fixture Menu 17 8 DMX Addressing 27 9 Operat...

Страница 4: ...e all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do...

Страница 5: ...d and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 Epileptic Warning Those suffering from epilepsy should avoid looking directly into the l...

Страница 6: ...sional 6 Design Spot LED Only handle the power cord by the plug Never pull out the plug by tugging the wire portion of the cord Please be aware that damages caused by manual modifications to the devic...

Страница 7: ...forming any service related issues 4 Never look directly into the light source You risk injury to your retina which may induce blindness 5 For safe operation follow the Installation guide described in...

Страница 8: ...tion with 16 prism macros Dimmer intensity from 0 100 User Selectable Power Supply Internal Tap Control board with full LCD character display and foil keyboard Reversible Display Option 180 Flip RDMX...

Страница 9: ...nimum distance between the fixture and a wall or flat surface should be at least 0 5 meter about 1 5ft Always install the fixture with an appropriate safety cable When installing the fixture in a susp...

Страница 10: ...fore taking into operation for the first time the installation has to be approved by an expert When installing the device make sure there is no highly inflammable material within a distance of min 0 5...

Страница 11: ...ial being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in...

Страница 12: ...through the center hole of the omega bracket As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrat...

Страница 13: ...res are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere...

Страница 14: ...DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head Please refer to the diagr...

Страница 15: ...ng a line terminator Elation part DMX T PACK will decrease the possibilities of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3...

Страница 16: ...nnels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the Design Spot LED which is a 16 channel fixture you should set the starting...

Страница 17: ...etting is saved the display will briefly readout OK to confirm a new setting has been made and locked into memory You may exit the main menu at any time without making any adjustments by tapping the M...

Страница 18: ...nt Tilt Reverse movement Pan Degree Select Movement Feedback switch Movement Mode Select Sensitivity of Mic Fans Control Auto Fans Speed High Fans Speed Low Fans Speed Fans Speed Mode Select Display S...

Страница 19: ...MX address Every device controlled by DMX has to have a unique starting address The addressing feature is what allows DMX to function properly The DMX address of a fixture is what allows it to communi...

Страница 20: ...idual scenes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time 7 1 5 Music control This function is similar to the Auto Progra...

Страница 21: ...the fixture in either Celsius or Fahrenheit Head Temp This function will display the internal head temperature of the fixture in real time 7 2 3 Software version This function will display the curren...

Страница 22: ...an movements Use the Up and Down buttons to turn this function On or Off Press the Enter button to accept the change or the Mode button to cancel and return to the main menu This function is OFF by de...

Страница 23: ...ardless of operating temperature 3 LOW The fans will remain in low speeds regardless of internal operating temperature 7 3 3 Display Settings Shutoff Time The display is designed to turn off during no...

Страница 24: ...fault This function is used to restore the fixture s original factory settings All settings will be set back to the default values shaded Any edited scenes will be lost 7 4 Reset Functions The reset f...

Страница 25: ...emely delicate procedure instruction on performing this action are left out of this manual For a first time calibrator please contact our customer support team for step by step instructions 7 6User Mo...

Страница 26: ...allows the user to edit or define the actual scenes that are stored in the user defined built in programs that are accessed in the previous step 7 7 4 Rec Controller The Design Spot LED features an i...

Страница 27: ...n volatile and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote D...

Страница 28: ...ddress between 256 and 511 3 Use channel 3 to set your desired DMX starting address For example If you want to set the starting address to 57 set channel 1 to a value of 7 set channel 2 to a value of...

Страница 29: ...nchronized light show without the need of an external controller The fixtures will react to sound chasing to a synchronized light show Set To Slave This function will set the fixture to slave mode for...

Страница 30: ...e previous Stand Alone section For the Slave units access the Set To Slave settings in the Function Mode menu and assign each slave fixture a designation Slave 1 Slave 2 Slave 3 etc 9 3 Universal DMX...

Страница 31: ...n a Program If you wish to build a static scene a scene consisting of no movement for a logo or gobo projection the scene must be stored inside a program To build scenes follow the instructions below...

Страница 32: ...me for the scene Input By Out this function will store a scene from an external DMX console See the next section for scene editing via an external DMX controller Step 1B Building Scenes from an Extern...

Страница 33: ...automatically lock the selected scene into the programs memory Repeat the process until all the desired scenes have been added to the program Each program can store a maximum of 64 scenes To test the...

Страница 34: ...ent pan fine CHANNEL 3 Tilt Movement max 265 CHANNEL 4 16bit Tilt Movement tilt fine CHANNEL 5 Color Wheel CHANNEL 6 Rotating Gobo Wheel CHANNEL 7 Gobo Index Gobo Rotation Speed Direction CHANNEL 8 Fi...

Страница 35: ...white 14 27 Red 28 41 Blue 42 55 Green 56 69 Yellow 70 83 Magenta 84 97 Orange 98 111 Light Blue 112 127 Pink 128 189 Forwards rainbow effect from fast to slow 190 193 No rotation 5 3 5 194 255 Backw...

Страница 36: ...exing Fixed Gobos 0 13 Open hole 14 27 Gobo 1 28 41 Gobo 2 42 55 Gobo 3 56 69 Gobo 4 70 83 Gobo 5 84 97 Gobo 6 98 111 Gobo 7 112 127 Gobo 1 shake slow to fast 128 143 Gobo 2 shake slow to fast 144 159...

Страница 37: ...e effect slow to fast 96 127 No function shutter open 128 159 Pulse effect in sequences 160 191 No function shutter open 192 223 Random strobe effect slow to fast 11 9 14 224 255 No function shutter o...

Страница 38: ...79 No function 80 84 All motor reset 85 87 Scan motor reset 88 90 Colors motor reset 91 93 Gobo motor reset 94 96 no function 97 99 Other motor reset 100 119 Internal program 1 secne1 8 of EEPROM 120...

Страница 39: ...en corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by...

Страница 40: ...pear after a fixture reset if the gobo positioning magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a stepper motor failure defective motor or a defective motor IC...

Страница 41: ...s of serious wear and should rotate freely 4 Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions...

Страница 42: ...Design Spot LED Elation Professional 42 Design Spot LED 14 PHOTOMETRIC DATA...

Страница 43: ...Design Spot LED Elation Professional 43 Design Spot LED 15 GOBOS...

Страница 44: ...Design Spot LED Elation Professional 44 Design Spot LED 16 DIMENSIONAL DRAWINGS...

Страница 45: ...Design Spot LED Elation Professional 45 Design Spot LED 17 CIRCUIT SCHEMATIC...

Страница 46: ...oduct Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been alte...

Страница 47: ...ties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shal...

Страница 48: ...2 7 fixed interchangeable gobos plus open Gobo outside diameter 26 9 mm image size 23 mm Gobo thickness glass 1 mm steel 0 15 mm Shutter Strobe Dimmer Strobe effect with variable speed 1 13 flashes p...

Страница 49: ...gn Spot LED Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Weight net 24Kgs 53 Lbs Fixture IP Rating IP20...

Страница 50: ...Design Spot LED Elation Professional 50 Design Spot LED...

Страница 51: ...Design Spot LED Elation Professional 51 Design Spot LED...

Страница 52: ...Rev 3 04 2010 visage Version 1 0 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Отзывы: