ACL 360I™ User Manual
E R R O R C O D E S
When power is applied, the unit will automatically enter a
“Motor Reset”
mode,
which brings all the internal motors to a home position. If there is an internal problem
with one or more of the motors, an error code (see below) will flash on the control
display.
ERROR CODE
DESCRIPTION
TILT Er
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or defective motor IC drive on main PCB). This error
may also be displayed if the head was blocked during a reset function
PAN Er
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during a
reset function.