1)  Determine the desired mounting location for the mirror

[A]

. Holding the wall 

mounting cleat

[D]

 against the wall, mark the locations required for the wall 

anchors

[B]

.

NOTE: Mirror should be mounted so that the touch dimming switch is at the very 

“bottom” of the mirror.

2)  Remove the wall mounting cleat from the wall, and use a 5/16” drill bit to drill pilot 

holes at the locations marked in step 1. Insert wall anchors into pilot holes. 

3)  Hold wall mounting cleat against the wall again, aligning holes in mounting cleat with 

the wall anchors. Screw the #8 screws

[C]

 through the holes in the wall mounting 

cleat, and into the wall anchors, until the wall mounting cleat is securely fastened 

tight against the wall. 

4)  Grounding instructions:

If fixture is provided with ground wire, connect fixture ground wire to outlet box 

ground wire with wire connector. Never connect ground wire to black or white power 

supply wires.

5)  Make wire connections. Reference chart below for correct connections and wire 

accordingly.

Connect Black or Red  

Supply Wire to:

Connect White Supply Wire 

to:

Black

White

*Parallel cord (round & 

smooth)

*Parallel cord (square & 

ridged)

Clear, Brown, Gold or Black 

without Tracer

Clear, Brown, Gold or Black 

with Tracer

Insulated wire (other 

than green) with copper 

conductor

Insulated wire (other than 

green) with silver conductor

*Note: When parallel wire (SPT 1 & 

SPT 2) are used. The neutral wire 

is square shaped or ridged and the 

other wire will be round in shape or 

smooth (See illus.)

Neutral Wire

6)  Hang mirror

[A]

 on wall by carefully lowering the hanger

[E]

 in the back of the mirror 

onto the wall mounting cleat

[D]

.

Fixture Diagram

Parts List

[A] 

Mirror

[B] 

Wall Anchors for 

3/8”- 1/2” Drywall 

[C] 

#8 Screws

[D] 

Wall Mounting Cleat

[E] 

Hanger

[F] 

Touch Dimming 

Switch

[G] 

Outlet Box

Cautions

IMPORTANT SAFETY INSTRUCTIONS

CAUTION – RISK OF SHOCK – 

Disconnect Power at the main circuit breaker panel or main fusebox before starting and 

during the installation. 
WARNING:

This fixture is intended for installation in accordance with the National Electrical Code 

(NEC) and all local code specifications. If you are not familiar with code requirements, 

installation by a certified electrician is recommended.
DIMMING: 

This LED fixture is not compatible with wall dimmer switches. Light output can only be 

adjusted by using the touch dimming switch on the bottom of the mirror.
CLEANING: 

Always be certain that electric current is turned off before cleaning.

• Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

Read all instructions before using this fixture.

When using an electrical furnishing, basic precautions should always be followed, 

including the following:
Read all instructions before using (this furnishing).
DANGER – To reduce the risk of electric shock:

1. Turn off mirror before cleaning.
WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:

1. Close supervision is necessary when this furnishing is used by, or near children, invalids, 

or disabled persons.

2. Use this furnishing only for its intended use as described in these instructions. Do not 

use attachments not recommended by the manufacturer.

3. Never operate this mirror if it has been dropped or damaged, or dropped into water. 

Return the mirror to a service center for examination and repair.

4. Never drop or insert any object into any opening.

5. Do not use outdoors.

Installation Instructions

For warranty information please visit: kichler.com/warranty

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1) 

This device may not cause harmful interference, and

2) 

This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will 

not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

FCC Information:

Cautions (continued)

6. Do not operate where aerosol (spray) products are being used or where oxygen is being 

administered.

7. WARNING: Risk of Electric Shock – Connect this furnishing to a properly grounded 

outlet only. See Grounding Instructions.

SAVE THESE INSTRUCTIONS

For household and commercial use.
Fixture Rating: 86004, 120Vac, 50/60Hz, 0.200A, 23W max

ON/OFF and Dimming Instructions

1)  To turn the light on or off, gently tap the touch dimming switch

[F]

 on the bottom of 

the mirror.

2)  To adjust the brightness level of the light, once the light is on, gently press and hold 

the touch dimming switch

[F]

 until the desired brightness setting is reached. If the 

light is turned off, it will remember this brightness setting when turned back on.

A

B

D

C

F

E

102 mm

        [4.0 in]

102 mm

        [4.0 in]

102 mm

        [4.0 in]

G

OFF

OFF

ON

UP

tap

tap

Отзывы: