background image

 

 

 

     

 

Revision 1.0. Released on 1

st

 of June, 2012. 

 

Installation and mounting manual for

 EK-XTOP D5 (Original CSQ) 

This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability 
whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions  are subject to change without notice. Please visit our web site at 

www.ekwb.com

 for updates. Before 

installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box. 
 

Before you start using this product please follow these basic guidelines: 

1.

 

Please carefully read the manual before through before beginning with the installation process! 

2.

 

The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.

 

3.

 

The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.

 

STEP 1:  PREPARING THE PUMP 

STEP 2: INSTALLING THE XTOP 

Unscrew the ribbed threaded ring that attaches the Laing pump’s 
original factory top and the main pump core housing with motor. 
Store the original top, the original o-ring gasket and the attaching 
ring in a safe place. 

 

 

1.

 

Install the EK-XTOP D5 on to the pump main 

motor housing. 

Make sure you install EK 

provided 61x3mm o-ring gasket! 

Reseat 

the gasket if needed. 
You can rotate the pump and use it in any 

direction to best suit your installation 

2.

 

Secure the XTOP D5 using enclosed M4x16 
DIN7380 screws with the enclosed Allen 

(hex) key. Do not over tighten the screws as 
excessive force may strip the threading. 

3.

 

Attach the mounting plate on the bottom of 
the pump top using the two enclosed 
countersunk M4x10 DIN7991 screws. 

 

STEP 3: ATTACHING FITTINGS 

 

Screw in the fittings in the G1/4 threaded openings on plastic top of the water block. EKWB recommends using EK-PSC fittings 
with the EK-XTOP D5 series pump tops. To ensure that the tubes are securely attached to the barb/fittings, please use hose 

clamps or an appropriate substitute. 
 

It is mandatory to use the correct INLET and OUTLET ports: 

1.

 

The OUTLET (pressure port) is the G1/4 threaded opening on the side of the pump top housing. Additional OUTLET port 
is located on the upper right edge of the pump’s front plate. Please refer to the picture on the right! 

2.

 

The INLET port (suction port) is the central G1/4 threaded opening on the EK-XTOP D5 front face plane. Please refer to 
the picture on the right! 

 

Use reservoir to feed the pump in order to prime it

Connect reservoir 

outlet

 port with EK-XTOP D5 

inlet

 port! 

 

This water pump & EK-XTOP D5 combo can be used in any mounting configuration (position) apart from being 
mounted upside down!

 

Mounting the pump upside down may result in pump running dry and eventually lead to 

premature failure of the pump! 

 

IMPORTANT DISCLOSURES: 

VERY  IMPORTANT  NOTICE:  Once  the  installation  is  completed,  it  is  a  recommended  practice  to  test  the  cooling  circuit  for  leaks  prior  to  powering  up  the  computer.  We 
recommend a 24 hour leak test prior to powering up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the 
block  unusable  (and  will  void  your  warranty).While  all  efforts  have  been  made  to  provide  the  most  comprehensive  tutorial  possible,  EK  Water  Blocks  assumes  no  liability 

expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either due to errors or omissions on 
our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

 
WARRANTY:Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this 
period, products will be repaired or have parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was   purchased; (II) the product 

has been purchased by an end user and has not used for commercial purposes;  (III) the product has not been misused, handled carelessly, or used in a manner other than in 
accordance  with the instructions provided describing its installation and proper use. This warranty does not confer rights other than those expressly set out above and does not 

cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is voided 
if the product comes in contact with aggressive UV additives or other improper liquids. 

 
Any other RMA issues can be reported t

[email protected]

 for further analysis. 

REQUIRED TOOLS 

      allen key 2.5mm

 

Factory original 

pump top 

D5 pump body with 

motor 

EK-XTOP D5 (Original CSQ) 

61x3mm sealing gasket (OR) 

D5 pump body with motor 

Screw M4x16 ISO7380 

From 

reservoir 

To radiator or water block 

Mounted upside down? 

NOT OK

Twist LEFT to unscrew! 

Mounting plate 

Alternative OUTLET port 