- 7 -
WHAT TO DO IN CASE YOU NOTICE A PRESSURE DROP
STEP 1
If the leak tester shows that the tested system or component is
leaking, first check that all fittings in the loop are firmly attached.
Verify that the components on the Leak Tester itself are not
loosened. Check that Flexible Tube`s Fittings on both sides,
Pressure Gauge, G1/4 Tube Connector with the O-ring and Pump
Connector are tightly attached.
STEP 2
In rare cases, debris can accumulate in the »Plastic Check Valve«
which causes it to lose pressure. You can check this by unscrewing
the “Pump connector” with an Allen key (size 4 mm) and removing
the Check Valve together with the Filter Foam. Gently push both of
them out of the Pump Connector using the same Allen key.
If you notice any debris in the Check Valve, remove or blow them
away and reassemble the Leak Tester. Remember to install the Filter
Foam back into the Pump Connector as well.
CHECK FOR
DEBRIS
STEP 2
STEP 1
PLASTIC
CHECK
VALVE
PLASTIC
CHECK VALVE
PUMP
CONNECTOR
O-RING
CHECK THAT ALL
COMPONENTS ARE
SECURELY FASTENED
FILTER FOAM