Installation and mounting manual for EK-FC R9-290X Lightning 

 

water block 

This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability 
whatsoever, expressed or implied, for the use of these products,  nor their installation. The  following instructions  are subject to change without notice. Please visit our web site at 

www.ekwb.com

 for updates.  Before 

installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box. 
 

Before you start using this product please follow these basic guidelines: 

1.

 

Please carefully read the manual before through before beginning with the installation process! 

2.

 

Please remove your motherboard from the computer to assure safest mounting process in order to prevent any possible damages to your CPU and/or motherboard’s circuit board (PCB).

 

3.

 

The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O-ring gaskets.

 

4.

 

The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.

 

STEP 1:  GENERAL INFORMATION.

 

Sample picture of MSI R9 290X Lightning graphics card 

 series graphics card.

 

STEP 2:  PREPARING YOUR GRAPHIC CARD. 

 

1. REMOVING STOCK COOLER: Remove four (4) encircled screws on 

the back of the PCB:  

 

 

STEP 2 cont.:  PREPARING YOUR GRAPHIC CARD  

1  cont...  REMOVING  STOCK  COOLER. 

Remove  the  stock  GPU  HSF  assembly.  Remove  two  (2) 

encircled screws attaching the metal plate to the circuit board as well as two (2) screws attaching the I/O 
bracket to the HSF. All heat sink assembly screws should be removed. 

 
  
                                        

 

2.  CLEANING THE  PCB. 

Carefully  detach  the  original  stock  cooler 

after  removing 

all

  screws  securing  it  to  the  board.  Wipe  off  the 

remains  (by  using  non–abrasive  cloth  or 

qtip

,  as  shown  on  sample 

photo)  of  the  original  thermal  compound  until  the  components  and 
circuit  board  are  completely  clean.  EKWB  recommends  the  use  of 
denatured alcohol for removing TIM leftovers. 

 

3. APPLYING THERMAL COMPOUND. 

Wipe off the remains 

(by using non–abrasive cloth or 

q-tip

) of the original thermal 

compound until the components and circuit board are 

completely clean. Apply thermal compound: lightly coat 

AMD 

GPU chip with enclosed EK-TIM Ectotherm thermal grease. 

EKWB recommends to apply thermal grease in cross form for 
best performance (see sample picture). 

  

4. CUTTING THERMAL PADS.

 Your block comes with thermal pads, some of which are already pre-cut. Others 

have to be cut to smaller chunks in order to cover all the VRM components such as MOSFETs and drivers. 
PLEASE REMOVE THE PROTECTIVE FOIL FROM 

BOTH SIDES OF THE THERMAL PADS PRIOR TO 
INSTALLATION. 

 

Replacement thermal pads: 
Thermal Pad D – 0.5mm (RAM 16x), 

Thermal Pad A – 1.0 mm (100x16mm)  

 

 
 

 

 

STEP 3:  INSTALLING THE WATER BLOCK 

 

PLACING THERMAL PADS ON PCB.

 Place thermal pads on chips so that numbers on chips match size of thermal pads. EKWB made sure users have more than enough 

pads to cover all surfaces that need to be covered to make block fully functional). EKWB recommends using small drops of  electrically non-conductive (for example: EK-
TIM Ectotherm, Arctic Cooling MX-2 ™, MX-4 ™ or GELID GC-Extreme™) thermal grease on each phase regulator (that is being covered with thermal pad) in order to 

even further improve the thermal performance of the EK-FC R9-290X Lightning block. 

                                                                                   

 

 

 
 
 
 

 2 

1: 

Thermal pad D – 0.5mm

 

(for memory IC): 

2: 

Thermal pad A – 1.0mm

 

(for VDD VRM): 

1  1  1  1  1  1  1  1 

 
 

 

 