background image

- 8 -

DISTRIBUTION PLATE CONFIGURATION

In order to complete your loop, all of the ports should be used as 
marked in the diagrams. 

One port of each type must be used.

 

In the eventuality that a GPU or CPU block is not installed into the 
system, the respective inlet and outlet ports must still be connected 
to each other.

When using Standalone pumps it is essential that the PUMP IN port 
is connected directly to the Inlet of the pump so that the impeller 
is always submerged during operation. Failure to do so will cause 
permanent damage to the pump.

To make installation of the tubing with different motherboard 
configurations easier, there are multiple connection options for the 
GPU. One of the inlet and one of the outlet ports must be used.

All remaining and unused ports should be closed using the supplied 
plugs and a 6mm Allen key.

EK recommends EK-Quantum Torque fittings.

GPU OUT

one must 

be used

GPU IN
one must 
be used

CPU OUT

CPU IN

FILL

RADIATOR 
OUT

DRAIN

DIRECTLY TO PUMP IN

Содержание 3831109821848

Страница 1: ...USER GUIDE EK Quantum InWin 909EK Silver Limited...

Страница 2: ......

Страница 3: ...you start using this product please follow the basic guidelines Carefully read the manual before you begin the installation process EK fittings require only a small amount of force to screw them firml...

Страница 4: ...CONTENT TECHNICAL SPECIFICATIONS 5 ACCESSORIES 5 DISTRIBUTION PLATE CONFIGURATION 8 PUMP INSTALLATION 9 RADIATOR AND FAN INSTALLATION 10 TESTING THE LOOP 11 CABLE MANAGEMENT GUIDES 11 SUPPORT AND SER...

Страница 5: ...ength up to 250mm Motherboard Compatibility ATX Micro ATX Mini ITX and E ATX up to 277mm wide Drive Compatibility two 3 5 or 2 5 drives in the bottom chamber Maximum GPU Length 365mm Maximum GPU Width...

Страница 6: ...ild Number Plate 1x 2 InWin 909EK Chassis Accessories M3x5 2 5 HDD Screws 10x M3x6 Fan Side Panel Spare Screws 6x Black M3x6 Fan Bracket Spare Screws 2x Nickel Motherboard Stand Off 11x Motherboard St...

Страница 7: ...re installed distribution plate with an integrated cable management solution In addition there are mounting holes provisioned for up to two D5 Standalone pumps two XE 480 Radiators and eleven Vardar 1...

Страница 8: ...ted directly to the Inlet of the pump so that the impeller is always submerged during operation Failure to do so will cause permanent damage to the pump To make installation of the tubing with differe...

Страница 9: ...9 PUMP INSTALLATION D5 Standalone pumps can be installed directly to the chassis using the supplied M4x8 Countersunk screws and pre drilled mounting holes...

Страница 10: ...AND FAN INSTALLATION Radiators and Fans may be mounted onto the 3 brackets outside of the case and then installed together EK recommends the use of ZMT 10 16mm tubing for the radiators and pumps to p...

Страница 11: ...ts in the reservoir CABLE MANAGEMENT GUIDES The InWin 909EK also includes Cable Guides which can be used to manage individually sleeved cables ensuring each wire stays parallel without the need to dis...

Страница 12: ...For assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU SUPPORT AND SERVICE...

Отзывы: