ektor 6100 Скачать руководство пользователя страница 1

1. Welcome

coDe:6100

coDe:6120

contents

Installation Instructions

1.

 Welcome

2.

  Safety Warnings

3.

  Advanced Wide Access Controller

4.

  Why Use an AWAC

5.

 Installation

6.

  AWAC Contents

7.

  AWAC Description

8.

  Functions and Status

9.

  AWAC Commissioning

10.

  Accessories List

11.

  Product Specifications

12.

  Warranty Information

13.

  Compliance Standards

14. 

Technical Support and Troubleshooting

Thank you for choosing this quality 
Ektor product. This manual is 
intended to help you install this 
product in a way that ensures the 
safety of yourself and others. Whilst 
this Ektor product is designed to be 
installed easily, we highly recommend 
you take the time to read this manual 
thoroughly before commencing 
installation. When installed correctly 
and serviced regularly, this product 
will provide hassle free operation for 
many years.

6100           EV-AWAC-KIT
6120           EV-WAC-INT2C

1

Содержание 6100

Страница 1: ... Standards 14 Technical Support and Troubleshooting Thank you for choosing this quality Ektor product This manual is intended to help you install this product in a way that ensures the safety of yourself and others Whilst this Ektor product is designed to be installed easily we highly recommend you take the time to read this manual thoroughly before commencing installation When installed correctly...

Страница 2: ...H THE TERMINAL BLOCK OR CIRCUITRY WHEN THE AWAC IS ENERGIzED 4 THERE ARE NO USER SERVICEABLE PARTS DO NOT ATTEMPT TO SERVICE ANY PARTS OF THE AWAC AS THIS WILL VOID THE WARRANTY 5 AS THE INSTALLER IT IS YOUR RESPONSIBILITY TO ENSURE YOU COMPLY TO ALL RELEVANT BUILDING AND SAFETY CODES FOR EXAMPLE THE BCA AS3000 REFER TO APPLICATION STANDARDS FOR THE RELEVANT RULES 6 WHEN INSTALLATION IS COMPLETE P...

Страница 3: ...i c e P rot e ct i v e De v i c e Protective Device L Protective Device To Lighting Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 Line 1 5 Installation The AWAC can be installed in two ways either as a small system or as a large system 5 1 AWAC wiring diagram Below is the suggested wiring diagram for the AWAC to a basic standalone emergency system It is suggested that the AWAC is installed at ...

Страница 4: ...he building Figure 2 Interconnecting AWACs Figure 3 Monitored System Wiring Close up Network Router To other Network Router Network Router To other Advanced Wired Access Controllers AWACs To other Advanced Wired Access Controllers AWACs To Wired Access Controller WACs AWAC 6100 EV Advanced Wired Access Controller To Wired Access Controller WACs ETHERNET SERIES ETHERNET ETHERNET ETHERNET SERIES AWA...

Страница 5: ...placed on each floor and connected to a central router It is possible to wire a number of floors to a single AWAC as long as the maximum cables runs are not exceeded Smaller networks are easier to commission and control however each line can support up to 64 emergency devices Figure 4 Typical Building Layout ...

Страница 6: ...WIRED ACCESS CONTROLLER installation instruction 6 The AWAC is sold as one kit including 1x Wired Access Controller WAC 1x Green Interlinking Cable 1x Advanced WideAccess Controller AWAC 6 AWAC CONTENTS 1 2 3 3 ...

Страница 7: ...8 AWAC FUNCTIONS AND STATUS The table below shows the status indicators of the buttons and status LEDs INDICATOR STATUS DESCRIPTION Web INFO WEB SERVICES 1 2 ERROR ON Short flashING 1 sec continous ON Flashing ON Flashing NOT USED Working A button has been pressed and a function begins A button is being pressed and held Webserver is on Webserver is off restarting System running Input error Restart...

Страница 8: ...d DALI line 1 will finish on its own Power on off for line 2 Addressed DALI line 2 will finish on its own Check if all are plugged into DALI line 1 Check if all devices are addressed Check if all are plugged into DALI line 2 Check if all devices are adressed PRESS HOLD 10 ACCESSORIES LIST Below are the listings of the compatible accessories for use with the AWAC PART EVOLT CODE CODE Wired ACcess c...

Страница 9: ... Wiring AWAC Weight Mounting Surface Mains Connection 6mm terminals 197 grams Field mounted DIN Rail 35mm Screw terminal for 1 4mm2 cable 230VAC 50Hz 0 08A 0 to 50 C IP20 Operating voltage V Operating frequency Hz Operating Current Operating Temperature IP Rating Wiring WAC Weight Mounting Surface Mains Connection 6mm terminals 175 grams Field mounted DIN Rail 35mm Screw terminal for 1 4mm2 cable ...

Страница 10: ...way or used other than in accordance with their instructions are not covered by this warranty This warranty is not transferrable and is valid only in the hands of the purchaser of the product The warranty does not cover Ektor products other than those purchased from Evolt Proof of purchase must be provided to Evolt with any warranty claim Evolt recommends that the purchaser attaches their proof of...

Страница 11: ...ents for miscellaneous electronic circuits used with luminaires IEC 61347 2 11 2001 MOD Particular requirements for miscellaneous electronic circuits used with luminaires Specification for equipment for general lighting purposes EMC immunity requirements Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Australian New Zealand Standa...

Страница 12: ...Ph 612 9502 1161 Fax 612 9502 1154 Email sales evolt com au evolt com au Reference 2015 110315 604418 V1 4 ...

Отзывы: