5.4
System information
The system information screen offers you a complete overview of the status and current
configuration of the
EL-
1000
-4GM
.
5.4.1
Status and diagnosis
On the actual status and diagnosis screen, an overview displays the currently activated and
deactivated protocols and functions in addition to the serial number, hard and software version of
the device. With the help of the editing buttons, you can directly change to the corresponding
protocols and functions to change the settings there.
5.4.2
Alarms/Notifications
The menu item alarms/notifications is used to define alarm triggers and alarm receivers. Alarm
triggers indicate which alarms of the software should be observed. If alarms occur for which an alarm
trigger is defined, then a log entry will be created and the Fail LED will be activated. In turn, alarm
receivers connected with the alarm trigger are informed or activated. Alarm triggers include, for
example:
a status change at a port
temperature that is too high or too low
a supply voltage outage
Media Redundancy Protocol Error
Wrong Neighbor in Profinet-Projects
Alarm receivers are:
two error relays
SNMP traps
E-mail addresses
The configured alarm assignments are displayed in lists with sequential IDs.
With the help of the alarm trigger and alarm receiver screen tabs, the view can be switched between: