© 2020 Eko Devices, Inc.
Model 2nd Generation
User Manual
Страница 1: ...2020 Eko Devices Inc Model 2nd Generation User Manual...
Страница 2: ...ation on network can listen to the auscultation sounds of a patient on site or at a different location on the network Eko CORE is intended for use on pediatric and adult patients The Eko CORE is inten...
Страница 3: ...ia Bluetooth that allows the user to open and playback sounds in a mobile application on compatible iOS and Android smartphones and tablets The App provides the ability for clinicians to save sounds w...
Страница 4: ...old waste Emits Radio Frequency signal Model number Humidity range Temperature range Wireless Bluetooth communication Manufacturer Manufacturing date Quantity IP22 indicates protection against access...
Страница 5: ...tethoscope near strong radio frequency RF signals or portable and or mobile RF devices and or specific RF emitters that are known sources of electromagnetic disturbance such as diathermy electrocauter...
Страница 6: ...ce and or turn the Bluetooth feature OFF Consult with your physicians when using the Eko device To ensure high quality sounds location and position of CORE placement should be taken into consideration...
Страница 7: ...ed in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipm...
Страница 8: ...licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m...
Страница 9: ...are no performance guarantees when using other stethoscope brands or models NOTE CORE is not compatible with Sprague stethoscopes or other digital stethoscopes Bluetooth and Data Connection In order t...
Страница 10: ...Pod Touch 6G and iPad 5th and 6th generations with iOS 12 0 and higher The mobile app software can also be used with Android devices with BLE support Bluetooth 4 0 and Android 8 0 and above CORE uses...
Страница 11: ...the chest piece from the tubing of the existing stethoscope Insert the chest piece into the Eko compatible adapter tubing provided Step Three Attach the tubing of the existing digital stethoscope to t...
Страница 12: ...from the surface of the volume buttons Power On Depress the power slider to move the switch from the OFF to the ON position ON is when the toggle is flush with the surface of the volume buttons Test...
Страница 13: ...Notes icon The Notes icon looks like a Post It with writing on it Select Add Note and begin typing your note Select the check mark to save Operating the CORE When using the CORE to assess and record...
Страница 14: ...e eartips are in your ears they should point forward Open the diaphragm When using a double sided stethoscope refer to Figure 3 you need to open or index the bell or diaphragm by rotating the chestpie...
Страница 15: ...sure autoclave sterilization processes If it becomes necessary to remove CORE pull the stethoscope tubing off of the metal stem of the CORE attachment on both ends Wipe all parts of the stethoscope cl...
Страница 16: ...may affect battery life No Modifications Failure to follow care and maintenance recommendations could result in damage to the internal components of CORE Internal damage to the product could cause ma...
Страница 17: ...oth settings in order to use CORE with the Eko App When using the Eko Dashboard and Eko App enable device and networking security features to protect patient data that is created and stored using this...
Страница 18: ...18 14a Eko App Provider Workflow Sign up Create your Eko account by entering in name and email address Turn on CORE Login Enter in your login credentials Pair CORE...
Страница 19: ...ow Start Recording Place CORE on the patient s chest Press the blue button to start recording Eko Settings Menu Adjust your settings by clicking on the top left home screen Save Recording Click save o...
Страница 20: ...20 14b Eko App Patient Workflow Sign up Turn on CORE Setup Pair CORE...
Страница 21: ...21 14b Eko App Patient Workflow Start recording Recording complete Recording in progress...
Страница 22: ...e in the electromagnetic environment specified below The user of the Eko Electronic Stethoscope System should assure that it is used in such an environment Applicable Emissions Test Compliance Electro...
Страница 23: ...dity should be at least 30 Electrical Fast Transient Burst IEC 61000 4 4 2 kV for supply lines 1 kV for input output lines Not Applicable Surge IEC 61000 4 5 1kV line s to line s 2 kV line s to earth...
Страница 24: ...cinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation...
Страница 25: ...aximum Output Power of Transmitter W Separation Distance According to Frequency of Transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1...
Страница 26: ...Oakland CA 94612 USA www ekohealth com 0537 Emergo Europe Prinsessegracht 20 2514 AP The Hague The Netherlands Australia Sponsor Emergo Australia 201 Sussex Street Darling Park Tower II Level 20 Sydne...