USER GUIDE

DISTRIBUTION PLATE

EK-Quantum 

Reflection Fractal ATX D5 PWM D-RGB – Plexi

Содержание Reflection Fractal ATX D5 PWM D-RGB - Plexi

Страница 1: ...USER GUIDE DISTRIBUTION PLATE EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi ...

Страница 2: ...ith the installation process The EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O ring gaskets The use of corrosion inhibiting coolants is always recommended for any liquid cooling system EKWB recommends any of the EKCryofuel for worry free usage ...

Страница 3: ...STRIBUTION PLATE IN THE DEFINE S2 MESHIFY S2 8 PREPARING THE DEFINE 7 7 XL 9 INSTALLING THE DISTRIBUTION PLATE IN THE DEFINE 7 7 XL 9 RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS 10 CONFIGURATION WITH ONLY TOP RADIATOR 10 CONFIGURATION WITH BOTH RADIATORS 11 CONNECTING THE D RGB LED STRIP 12 CONNECTING THE PUMP 13 TESTING THE LOOP 13 SUPPORT AND SERVICE 14 SOCIAL MEDIA 14 ...

Страница 4: ...ly read the PC case manual STEP 1 Remove the both side panels and the front panel from the case STEP 1 STEP 2 STEP 2 Remove the top filter frame and follow the process in the Fractal Design R6 case manual to remove all drive mounts and re position the drive cover to the back of the case ...

Страница 5: ... Unscrew two 2 encircled screws and use the marked holes for distribution plate mounting screws You can also remove the drive cover in order to secure the distribution plate with additional mounting screws if required ...

Страница 6: ... Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate into the PC case Make sure that mounting holes are aligned STEP 1 STEP 2 STEP 2 Secure the EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate with two M3 x 10 7984DIN screws and steel washers Steel Washer M3 X 10 DIN7984 ...

Страница 7: ...he distribution plate carefully read the PC case manual STEP 1 Remove the both side panels from the case STEP 1 STEP 2 STEP 2 Remove the hard drive cage It can be reused after installing EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate ...

Страница 8: ...tion Fractal ATX D5 PWM D RGB Plexi distribution plate into the PC case Make sure that mounting holes are aligned STEP 1 STEP 2 STEP 2 Secure the EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate with enclosed M3 X 10 7984DIN mounting screws and steel washers Steel Washer M3 X 10 7984DIN ...

Страница 9: ...B Plexi distribution plate STEP 1 INSTALLING THE DISTRIBUTION PLATE IN THE DEFINE 7 7 XL STEP 1 Carefully place the EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate into the PC case Make sure that mounting holes are aligned STEP 2 Secure the EK Quantum Reflection Fractal ATX D5 PWM D RGB Plexi distribution plate with M3 x 10 7984DIN screws and steel washers STEP 1 2 Steel Wa...

Страница 10: ... WITH ONLY TOP RADIATOR All remaining and unused ports should be closed using the supplied plugs and an EK Loop Multi Allen Key 6mm 8mm 9mm CPU OUTLET CPU INLET GPU INLET One must be used GPU OUTLET One must be used FILL DRAIN TOP RADIATOR INLET TOP RADIATOR OUTLET ...

Страница 11: ...ed ports should be closed using the supplied plugs and an EK Loop Multi Allen Key 6mm 8mm 9mm CPU OUTLET CPU INLET GPU INLET One must be used GPU OUTLET One must be used FILL DRAIN TOP RADIATOR INLET TOP RADIATOR OUTLET FRONT RADIATOR OUTLET FRONT RADIATOR INLET ...

Страница 12: ...e arrow indicated on the connector is pluggedintothe 5Vlineasindicatedonyourmotherboard If you put LED Diode to the 12V RGB HEADER you can damage the LEDs Connector is the same on D RGB and RGB versions but D RGB version has 3 cables from connector to PCB RGB version has 4 cables If you connect D RGB led to ordinary RGB header you can damage your motherboard or LED strip CONNECTING THE D RGB LED S...

Страница 13: ...make sure the installation of EK components was successful we recommend you perform a leak test for 24 hours When your loop is complete and filled with coolant connect the pump to a PSU outside of your system Do not connect power to any of the other components Turn on the PSU and let the pump run continuously It is normal for the coolant level to drop during this process as air collects in the dis...

Страница 14: ...or assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...