Commissioning
7.3 Description of OSD menu
SCD 19102 / SMD 19102
48
Instruction Manual, 05/2008, A5E01588521A-002
Main menu
Function
Adjustment/range
Description
Signal adjustment
Switch loop
1 … 20
Default: 1
The following four
parameters are of relevance
for this tool:
•
H-frequency
•
V-frequency
•
V-total
•
Interlaced/non Interlaced
If one of these parameters
changes, the display treats it
as a timing change and
initiates resynchronization
via an "Auto in progress". To
prevent this from happening
as a result of each and every
minor signal disturbance, the
value representing the
permissible number of faulty
or changed frames must be
increased in the case of
unstable signal sources.
Disadvantage:
The higher the tab setting,
the longer it will take for a
desired timing change to
occur (delayed by a number
of milliseconds).
Tolerance factor
1 … 20
Default: 1
This tool only considers the
H and V frequencies.
An increase in the tab value
results in a larger tolerance
band being defined. Minor
frequency fluctuations within
this range will not result in
resynchronization ("Auto in
progress").
Signal (only for analog
signal)
RGB
Monochrome
Default:
•
RGB
(for SCD19102)
•
Monochrome
(for
SMD19102
)
Switch over signal between
b/w and color operation
•
If a monochrome signal
arrives, it is green on the
color display.
•
To obtain correct b/w
images, set the "Signal"
parameter to
monochrome.
Содержание SCD 19102
Страница 2: ......
Страница 8: ...Table of contents SCD 19102 SMD 19102 8 Instruction Manual 05 2008 A5E01588521A 002...
Страница 14: ...Safety notes SCD 19102 SMD 19102 14 Instruction Manual 05 2008 A5E01588521A 002...
Страница 18: ...Description 3 3 Important features SCD 19102 SMD 19102 18 Instruction Manual 05 2008 A5E01588521A 002...
Страница 20: ...Application planning 4 1 Installation site SCD 19102 SMD 19102 20 Instruction Manual 05 2008 A5E01588521A 002...
Страница 22: ...Assembly 5 1 Mounting of unit SCD 19102 SMD 19102 22 Instruction Manual 05 2008 A5E01588521A 002...
Страница 34: ...Connecting 6 9 Serial interface SCD 19102 SMD 19102 34 Instruction Manual 05 2008 A5E01588521A 002...
Страница 72: ...Operation 8 2 Switching on the display SCD 19102 SMD 19102 72 Instruction Manual 05 2008 A5E01588521A 002...
Страница 76: ...Troubleshooting SCD 19102 SMD 19102 76 Instruction Manual 05 2008 A5E01588521A 002...
Страница 92: ...Accessories 13 4 Graphics cards SCD 19102 SMD 19102 92 Instruction Manual 05 2008 A5E01588521A 002...
Страница 103: ......
Страница 104: ...EIZO GmbH Display Technologies Siemensallee 84 76187 KARLSRUHE GERMANY www eizo eu Order No A5E01588521A 002...