background image

4 | Specifications

30

4.1.8 Transport / Storage Conditions

Temperature

-20˚C – 60˚C

Humidity

10 % – 90 % R.H. (no dew condensation)

Air Pressure

200 hPa – 1060 hPa

4.2 Compatible Resolutions

The monitor supports the following resolutions.

: Supported, -: Not supported

Resolution

Vertical scan

frequency (Hz)

DisplayPort

DVI

Portrait

Landscape

Portrait

Landscape

720 x 400

70.087

640 x 480

59.940

800 x 600

60.317

1024 x 768

60.004

1280 x 1024

60.020

-

-

1600 x 1200

*1

60.000

-

-

1200 x 1600

*1

59.963

-

-

*1

Recommended resolution

4.3 Accessories

The following accessories are available separately.

For the latest information about the optional accessories and information about the latest
compatible graphics board, refer to our web site.

(

www.eizoglobal.com

)

Calibration Kit

RadiCS UX2 Ver.5.1.0 or later

RadiCS Version Up Kit Ver.5.1.0 or later

Network QC Management Software

RadiNET Pro Ver.5.1.0 or later

Cleaning Kit

ScreenCleaner

Comfort Light for Reading Rooms

RadiLight

Arm

AAH-02B3W

LA-011-W

Panel Protector

RP-915

VESA Adapter for Thin Client or Mini-PC

PCSK-R1

Signal Cable (DVI-D - DVI-D)

DD300

DD200

Содержание RadiForce RX270

Страница 1: ...Instructions for Use and Installation Manual before use Please retain this manual for future reference See the Installation Manual for monitor settings and adjustments The latest product information including the Instructions for Use is available on our web site www eizoglobal com ...

Страница 2: ...justed specifically for use in the region to which it was originally shipped If operated outside this region the product may not perform as stated in the specifications No part of this manual may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical or otherwise without the prior written permission of EIZO Corporation EIZO Corporation is under ...

Страница 3: ...or Location of Caution Statement Symbols on the unit Symbol This symbol indicates Main power switch Press to turn the monitor s main power off Main power switch Press to turn the monitor s main power on Power button Press to turn the monitor s power on or off Alternating current Alerting electrical shock hazard CAUTION See SAFETY SYMBOLS 2 WEEE marking Product must be disposed of separately materi...

Страница 4: ...deral law USA restricts this device to sale by or on the order of a licensed healthcare practitioner Medical device in the EU Importer in the EU Mark signifying compliance with UK regulations UK Responsible Person Authorised representative in Switzerland ...

Страница 5: ...to service this product yourself as opening or removing covers may result in fire electrical shock or equipment damage WARNING Keep foreign objects or liquids away from the unit Metal parts flammable materials or liquids accidentally falling into the cabinet may result in fire electrical shock or equipment damage If an object or liquid falls spills into the cabinet unplug the unit immediately Have...

Страница 6: ...corrosive gases such as sulfur dioxide hydrogen sulfide nitrogen dioxide chlorine ammonia and ozone Do not place in environments with dust components that accelerate corrosion in the atmosphere such as sodium chloride and sulfur conductive metals and so on WARNING Keep the plastic packing bags away from babies and children The plastic packing bags may cause suffocation WARNING Use the enclosed pow...

Страница 7: ...jury and or equipment damage Before installation make sure that desks walls or any other installation surface has adequate mechanical strength If the unit falls disconnect the power immediately and ask your local EIZO representative for advice Do not continue using a damaged unit Using a damaged unit may result in fire or electrical shock When reattaching the tilt stand please use the same screws ...

Страница 8: ...When moving the product hold the bottom of the monitor firmly Monitors of size 30 inches and above are heavy When unpacking and or carrying the monitor ensure at least two people are utilized If your device model has a handle on the back of the monitor grasp and firmly hold the bottom and handle of the monitor Dropping the unit may result in injury or equipment damage CAUTION Exercise care not to ...

Страница 9: ...e cleaning it Cleaning the unit while it is plugged into a power outlet may result in electrical shock CAUTION If you plan to leave the unit unused for an extended period of time disconnect the power plug from the wall socket after turning off the power switch for the safety and the power saving CAUTION Dispose of this product in accordance with the laws of the locality or country of residence CAU...

Страница 10: ... long period of time smudges or burn in may appear To maximize the life of the monitor we recommend the monitor be turned off periodically The backlight of the LCD panel has a fixed lifetime Depending on the usage pattern such as usage for long continuous periods the lifespan of the backlight may run out sooner requiring replacement When the screen becomes dark or begins to flicker please contact ...

Страница 11: ...nsor that is sold separately perform correlation between the Integrated Front Sensor and the external sensor using RadiCS RadiCS LE Periodical correlation allows you to maintain the measurement result of the Integrated Front Sensor at a level equivalent to that of the external sensor Attention The display status of the monitor may change unexpectedly due to an operating error or unexpected setting...

Страница 12: ...ibitane solution Alcohol based Benzalkonium chloride Welpas Aldehyde based Glutaral Sterihyde Aldehyde based Glutaral Cidex Plus28 To Use the Monitor Comfortably An excessively dark or bright screen may affect your eyes Adjust the brightness of the monitor according to the environmental conditions Staring at the monitor for a long time tires your eyes Take a 10 minute rest every hour Look at the s...

Страница 13: ...lay 15 1 1 2 Simple wiring 15 1 1 3 Quality control 15 1 1 4 Equipped with USB Type C quick charge function 16 1 1 5 Space saving design 16 1 1 6 Monitor operation from the mouse and keyboard 16 1 2 Package Contents 17 1 2 1 EIZO LCD Utility Disk 17 1 2 2 RadiCS LE 17 1 2 3 To use RadiCS LE 18 1 3 Controls and Functions 19 1 3 1 Front 19 1 3 2 Back 20 2 Installation Connection 21 2 1 Before instal...

Страница 14: ...quirements 29 4 1 8 Transport Storage Conditions 30 4 2 Compatible Resolutions 30 4 3 Accessories 30 Appendix 31 Medical Standard 31 Classification of Equipment 31 EMC Information 32 Environments of Intended Use 32 Technical Descriptions 33 Information for Radio Interference 39 For U S A Canada Only 39 Declaration of compliance with India RoHS 40 ...

Страница 15: ...wiring In addition to a DisplayPort input terminal an output terminal is also provided From the output terminal a signal can be output to a different monitor 1 1 3 Quality control This monitor has a built in calibration sensor Integrated Front Sensor This sensor enables the monitor to perform calibration SelfCalibration and Grayscale Check independently Using the included RadiCS LE allows you to p...

Страница 16: ...ration from the mouse and keyboard Using the RadiCS RadiCS LE monitor quality control software you can perform the following monitor operations using the mouse and keyboard Switching CAL Switch modes Switching input signals Function that assigns any CAL Switch mode to a part of the screen and displays an image Point and Focus Switching PCs that use USB devices Switch and Go Entering power saving m...

Страница 17: ...ity Disk The CD ROM contains the following items Refer to Readme txt on the disk for software startup procedures or file reference procedures Readme txt file RadiCS LE monitor quality control software for Windows User s Manual Instructions for Use of this monitor Monitor Installation Manual RadiCS LE User s Manual Outline dimensions 1 2 2 RadiCS LE RadiCS LE enables you to perform the following qu...

Страница 18: ...oster A feature that automatically adjusts monitor brightness to match the ambient light level when set to Text mode Auto Brightness Control Attention The specifications of RadiCS LE are subject to change without notice The latest version of RadiCS LE is available for download from our web site www eizoglobal com 1 2 3 To use RadiCS LE For information on how to install and use RadiCS LE refer to R...

Страница 19: ...Environmental illumination measurement is performed using the RadiCS RadiCS LE quality control software 3 Operation switches Displays the operation guide Set menus according to the operation guide 4 switch Turns the power on or off The switch indicator is lit when you turn the power on The indicator color differs depending on the monitor s operation status Green Normal operation mode Orange Power ...

Страница 20: ...SB downstream port Connect it to a USB device To set up a daisy chain connection connect the cable to the USB upstream port of another monitor 5 Main power switch Turns the main power on or off Off On 6 Security lock slot Complies with Kensington s MicroSaver security system 7 Cable holder Holds the monitor cables 8 USB Type B connector USB upstream port Connect this port to the PC when you use so...

Страница 21: ... lacquer coated desk the color may adhere to the bottom of the stand due to the composition of the rubber Check the desk surface before use 2 1 1 Installation conditions When installing the monitor in a rack ensure that there is adequate space around the sides back and top of the monitor Attention Position the monitor so that there is no light to interfere with the screen ...

Страница 22: ...ct the cables After connecting the DVI cable tighten the fasteners to secure the connector Signal cable DD300 DD200 or Signal cable PP300 optional Attention The DisplayPort connectors of the monitor consist of input and output connectors When connecting the monitor to a PC connect the cable to the input connector When connecting to multiple PCs switch the input signal For details refer to the Inst...

Страница 23: ... Remove the cap before connecting the signal cable Signal cable PP300 Signal cable PP300 Connect to PC 2 Plug the power cord into a power outlet and the power connector on the monitor Insert the power cord fully into the monitor 3 Connect the USB cable to the monitor s USB upstream port and to the PC s USB downstream port respectively The cable connection is required when you use RadiCS RadiCS LE ...

Страница 24: ...er switch is located 2 Turn on the PC The screen image appears If an image does not appear see 3 No Picture Problem 26 for additional advice Attention When connecting for the first time or changing the connection method display settings such as resolution and display scale may not be appropriate Check if the settings for the PC are properly configured For power saving purposes it is recommended th...

Страница 25: ...ht edges of the monitor with both hands and adjust the screen height tilt and swivel the screen to the optimum position for performing tasks Attention After the adjustment is finished make sure that the cables are correctly connected After adjusting the height and angle pass the cables through the cable holder ...

Страница 26: ...n the input signal is used for output when a daisy chain connection is set up Turn off the main power and then turn it on again Power switch indicator blinks Orange Green Connect via the signal cable specified by EIZO Turn off the main power and then turn it on again If the signal cable is connected to DisplayPort 1 try switching the DisplayPort version For details refer to the Installation Manual...

Страница 27: ...s set up Turn off the main power and then turn it on again The message Signal Error appears on the screen Example Check whether the PC is configured to meet the resolution and vertical scan frequency requirements of the monitor see 4 2 Compatible Resolutions 30 Reboot the PC Select an appropriate setting using the graphics board s utility Refer to the User s Manual of the graphics board for detail...

Страница 28: ... colors from a palette of approx 543 billion colors Viewing Angle H V typical 178 178 Recommended Brightness 500 cd m2 Contrast Ratio typical 1800 1 Response Time typical 20 ms black white black 4 1 3 Video Signals Input Terminals DisplayPort x 2 DVI D Single Link x 1 Output Terminals DisplayPort x 1 Horizontal scan frequency 31 kHz 100 kHz Vertical scan frequency 1 59 Hz 61 Hz 720 x 400 69 Hz 71 ...

Страница 29: ... not connected Power Save High DP Power Save On DisplayPort 1 Version 1 1 no external load is connected 2 When the USB upstream port is not connected DP Power Save On DisplayPort 1 Version 1 1 no external load is connected 4 1 6 Physical Specifications Dimensions W x H x D 356 5 mm x 482 3 mm 572 3 mm x 200 0 mm Tilt 0 356 5 mm x 509 9 mm 599 9 mm x 276 5 mm Tilt 30 Dimensions W x H x D Without St...

Страница 30: ...1200 1 60 000 1200 x 1600 1 59 963 1 Recommended resolution 4 3 Accessories The following accessories are available separately For the latest information about the optional accessories and information about the latest compatible graphics board refer to our web site www eizoglobal com Calibration Kit RadiCS UX2 Ver 5 1 0 or later RadiCS Version Up Kit Ver 5 1 0 or later Network QC Management Softwa...

Страница 31: ...gnetic waves that could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment where such effects are avoided Classification of Equipment Type of protection against electric shock Class I EMC class IEC60601 1 2 2014 Group 1 Class B Classification of medical device EU Class I Mode of operation Continuous IP Class IPX0 ...

Страница 32: ...ial precautions regarding EMC and need to be installed You need to carefully read EMC Information and the PRECAUTIONS section in this document and observe the following instructions when installing and operating the product WARNING The RadiForce series should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the equipment or system should be observed t...

Страница 33: ...romagnetic emissions The RadiForce series is intended for use in the electromagnetic environment specified below The customer or the user of the RadiForce series should assure that it is used in such an environment Emission test Complian ce Electromagnetic environment Guidance RF emissions CISPR11 EN55011 Group 1 The RadiForce series uses RF energy only for its internal function Therefore its RF e...

Страница 34: ...al environment Surges IEC EN61000 4 5 1 kV line to line 2 kV line to ground 1 kV line to line 2 kV line to ground Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC EN61000 4 11 0 UT 100 dip in UT 0 5 cycles and 1 cycle 70 UT 30 dip in UT 25 cycles 50 Hz 0 UT 100 dip in UT 250 cy...

Страница 35: ...ce level in each frequency range 2 Interference may occur in the vicinity of equipment marked with the following symbol Note UT is the a c mains voltage prior to application of the test level At 80 MHz and 800 MHz the higher frequency range applies Guidelines regarding conducted disturbances induced by RF fields or radiated RF fields may not apply in all situations Electromagnetic propagation is a...

Страница 36: ... abnormal performance is observed additional measures may be necessary such as reorienting or relocating the RadiForce series 2 Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m ...

Страница 37: ...aximu m power W Minimum separatio n distance m IEC EN60601 test level V m Complia nce level V m 385 380 390 TETRA 400 Pulse modulation 2 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviation 1 kHz sine 2 0 3 28 28 710 704 787 LTE Band 13 17 Pulse modulation 2 217 Hz 0 2 0 3 9 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation 2 18 Hz 2 0 3 28 28...

Страница 38: ... 150 kHz 80 MHz d 1 2 P 80 MHz 800 MHz d 1 2 P 800 MHz 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the...

Страница 39: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Страница 40: ...f the following substances except for the exemptions listed in schedule II Lead Mercury Hexavalent Chromium Polybrominated Biphenyls or Polybrominated Diphenyl Ethers exceeding a concentration of 0 1 by weight in homogeneous materials Cadmium exceeding a concentration of 0 01 by weight in homogeneous materials For information on proper disposal and recycling of the product please refer to the foll...

Страница 41: ...served 2nd Edition September 15th 2022 153 Shimokashiwano Hakusan Ishikawa 924 8566 Japan Carl Benz Straße 3 76761 Rülzheim Germany 中国苏州市苏州工业园区展业路8号中新科技工业坊5B 1 Queens Square Ascot Business Park Lyndhurst Road Ascot Berkshire SL5 9FE UK Moosacherstrasse 6 Au CH 8820 Wädenswil Switzerland ...

Отзывы: