Drawing   : - TPC433 
Issue 

: - 2 

Date 

: - 24/11/16 

 
 

RM85 

SPARE PARTS LIST 

    

    

    
    
    
    
    
    

N

UMBER

 

D

ESCRIPTION

 

P

ART 

N

UMBER

 

Q

UANTITY

 

Timer 

1619508 

Condenser coil 

2029322 

Evaporator coil 

2029323 

Cable & Tube wrap 

2056002 

Drain tray 

2056003 

Filter 

2056004 

Capillary 

3014254 

2 X 2ft 

Solenoid valve 

3020837 

Filter dryer 

3020909 

10 

Compressor 

3022198 

11 

Defrost Relay 

3030269 

12 

Solenoid coil 

3030451 

13 

Humidity Controller 

3031530 

14 

Run capacitor 

3030908 

13 

On/Off switch 

3035914 

14 

Power Relay 

3036157 

16 

Pump purge switch 

3036779 

17 

Fan 

3040277 

18 

Fan inlet ring 

3040283 

19 

Wheel 

3050124 

20 

Rubber foot 

3101436 

21 

Condensate pump 

3160150 

Содержание 10560RH-US

Страница 1: ...Page 1 of 12 Drawing TPC433 Issue 2 Date 24 11 16 RM85H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...2 of 12 Drawing TPC433 Issue 2 Date 24 11 16 RM85H PACKAGE CONTENTS Item Description Quantity 10560RH US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC433 Manu...

Страница 3: ...e cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor The air is ther...

Страница 4: ...erants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data labe...

Страница 5: ...ned The required humidity level can be set as follows Press the S button once to access the set point Press the or button to change the display to the desired Humidity level Press the S button again t...

Страница 6: ...t melting This is quite normal and the display will return to its normal reading when the unit returns to dehumidifying mode Fan running If after carrying out the above procedures the unit does not ap...

Страница 7: ...r than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5 In order to check the defrost operati...

Страница 8: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 9: ...fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass va...

Страница 10: ...6 Filter 2056004 1 7 Capillary 3014254 2 X 2ft 8 Solenoid valve 3020837 1 9 Filter dryer 3020909 1 10 Compressor 3022198 1 11 Defrost Relay 3030269 1 12 Solenoid coil 3030451 1 13 Humidity Controller...

Страница 11: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Страница 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...