27
WWW.EILERSEN.COM
–
Check load cell serial no., exponent and capacity
In the
LOAD CELL INFO.
screen, the load cell serial number, exponent and capacity can be
read for the individual load cells:
On each line for each load cell the serial number, exponent and capacity as well as in paren-
thesis the capacity converted to an appropriate unit depending on the exponent is shown.
Please notice:
If a line is flashing this indicates, that an error code is present for the corre-
sponding load cell. This can be examined further using the
STATUS
and
LOAD CELL INFO.
screens.
–
Check individual load cell signals
In the
LOAD CELL SIGNALS
screen, the individual load cell readings can be checked:
Three different readings can be selected from the
LOAD CELL SIGNALS
menu:
DIRECT
The internal load cell output value is displayed as it is received. This number is in SI units, but
the resolution is load cell dependent and may be an unusual value like 100mg, 10 gr. etc. Fur-
thermore no zeroing is used and the load cell value will NOT be 0 when the load cell is empty,
so this value is NOT the absolute load on this load cell.