INSTALLATION INSTRUCTIONS
LED Wallpack - Trapezoid
SAFETY PRECAUTION:
• WARNING: To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected,
and maintained by a qualified electrician only, in accordance with all applicable electrical codes
• WARNING: To avoid electric shock be certain electrical power is OFF before and during installation and
maintenance.
• WARNING: To avoid electric shock luminaire must be connected to a wiring system with an equipment-
grounding conductor.
• WARNING: Make sure the supply voltage is the same as the rated luminaire voltage.
• WARNING: Do not install where marked operating temperatures exceed the ignition temperature of the
hazardous atmosphere.
• WARNING: Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
SUITABLE FOR USE IN WET LOCATIONS
FOR SUPPLY CONNECTIONS USE WIRE RATED FOR AT LEAST 80°C.
AMBIENT TEMP: -20°C (-4°F) TO 40°C (104°F)
INSTALLATION:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
EiKO Global, LLC • 23220 W. 84th St, Shawnee, KS 66227 • (P) 1-800-852-2217 • (F) 1-800-492-8975 • eiko.com
EiKO Canada • 81 King St, Barrie, Ontario L4N 6B5 • (P) 1-705-721-5189 • (F) 1-705-721-7855 • [email protected]
Rev. 7/20/2017
1. Open the back of the box by using a philips screw driver. (
See Fig. 1) Refer to the size indicated on the diagram to
bore holes into the wall.
(
See Fig. 2
)
2. Screw the two green/yellow grounding cords to the position which is indicated “GR” (
See Fig. 3
)
3. Install the rear cover on the wall and connect the supply lines, referring to the circuit diagram (
See Fig. 5
)
4. Tighten enclosure screws to seal fixture. (
See Fig. 4
)
5
LED DRIVER
SUPPLY LINE (BLACK)
SUPPLY NEUTRAL
(WHITE)
SUPPLY GROUNDING
(GREEN)
FACTORY WIRED
LED TO DRIVER
LINE (BLACK)
NEUTRAL
(WHITE)
BOX GROUNDING (GREEN)
1
2
6.59” (167.5
mm
)
5.73” (145.5mm)
3
4
GR