Instructions

Read and retain carefully for as long as the product is being used. It contains vital information on the operation 
and installation. This booklet should be regarded as part of the product.
If you are just installing the Alarm, this booklet must be given to the householder. This booklet is to be given to 
any subsequent user.

Model: Ei168RC

RadioLINK

Alarm Base

Содержание RadioLINK Ei168RC

Страница 1: ...ontains vital information on the operation and installation This booklet should be regarded as part of the product If you are just installing the Alarm this booklet must be given to the householder Th...

Страница 2: ...guide 3 Installation 4 Troubleshooting the RF link 5 Checking maintaining the alarm system 6 Technical specification 7 Guarantee 8 Limitations of radio communications 9 Getting the RadioLINK Base serv...

Страница 3: ...aces the amber LED The primary function of the RadioLINK base is to interconnect all Alarms in the system i e when one Alarm senses fire the Ei168RC base attached to that Alarm will transmit an RF sig...

Страница 4: ...n activated by nuisance unwanted alarms Remote Locating This will silence all the Alarms in the system except the one sensing the fire Remote Silencing This will silence all the Alarms in the system M...

Страница 5: ...INK System Alarm Controller Hardwired interconnect Wireless interconnect Alarm Controller In this configuration the alarm controller must be a RadioLINK device It is not possible to control the system...

Страница 6: ...nsult your supplier or contact tech support see back page Install each RadioLINK Base in the centre of the ceiling at least 0 30m from light fittings as per the Smoke Heat Alarm instructions and conne...

Страница 7: ...the RadioLINK Bases are House Coded Press and hold the Button to test each Alarm Check that the red light is flashing the horn is sounding To ensure the Alarm is communicating with others check that...

Страница 8: ...roughout the premises for Live Neutral and Interconnect wires if used WARNING WARNING WARNING The Ei168RC must NOT be connected when the house wiring insulation is being checked with high voltages i e...

Страница 9: ...tion as shown in the diagram above This will ensure that all the antennas are in parallel which will maximise the RF signal strength 9 Orientate Latch to point to front wall Orientate all RadioLINK ba...

Страница 10: ...ains supply from the circuit that is going to be used Remove the cover from the terminal block as shown here Bring the mains wires through the ceiling and thread them through the hole in the rear of t...

Страница 11: ...inserted at the end of this procedure to secure the base permanently Connect the wiring to the terminal block as shown here L Live connect to the house wires coloured brown or marked L N Neutral conne...

Страница 12: ...ht flashes every 10 seconds remove the alarm and manually depress the rechargeable cell on switch as shown and refit the alarm If there is still a problem the cells may be depleted so leave the unit o...

Страница 13: ...code the system may also result in a system malfunction Press and hold the House Code switch on the side of any one of the RadioLINK Bases with a small screwdriver until the blue light illuminates Imm...

Страница 14: ...l flash 5 times and repeat this pattern every 5 to 10 seconds To complete the commissioning the system must exit house code mode The units will automatically exit house code after 30 minutes Once the...

Страница 15: ...ng the test hush button for up to 20 seconds on each unit in turn The red light will flash the Alarm will sound and blue light on the RadioLINK Base sidewall will illuminate continuously for around 3...

Страница 16: ...lot on the base as shown here The blue light will come on solid Hold the screwdriver in position until the blue light starts to flash 6 seconds approx and then release the screwdriver When all devices...

Страница 17: ...the next alarm allow a minimum of one minute after the last alarm has stopped sounding from the previous test ii Ensure all bases are orientated the same way with respect to the front wall of the dwel...

Страница 18: ...n Rotating and or relocating the units may move them out of the range of existing units even though they may have already been House Coded correctly in the system It is important therefore to check th...

Страница 19: ...e mounting plates when the premises are re occupied Long term storage over 1 year can damage the batteries such that they will not recharge when the units are re connected to the mains supply Check th...

Страница 20: ...for around 3 5 seconds Continue to hold the test button until all the Alarms in the system are sounding This will take between 20 to 45 seconds depending on the number of Alarms in the system e g a s...

Страница 21: ...of the mains rechargeable cell back up is checked directly after installation and then at least yearly N B If the blue light is flashing refer to page 12 End of Life EOL Check Check the replace unit...

Страница 22: ...Range 0oC to 40oC Cat 3 Humidity 15 95 Non Condensing Receiver Category Cat 2 RF Performance EN 300 220 EMC Performance EN 301 489 RF Power 5dBm min Range 100 meters in free space Multi Repeater Rang...

Страница 23: ...ion of units If the product should become defective within the guarantee period it may be returned with proof of purchase carefully packaged and with the problem clearly stated to the place of purchas...

Страница 24: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause interference to radio and or television reception However there is no guarantee th...

Страница 25: ...nt lightly press the off switch to disconnect the rechargeable cells and put both the Alarm and the Ei168RC RadioLINK Base in a padded box and send it to Customer Assistance and Information at the nea...

Страница 26: ...other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer...

Страница 27: ...27...

Страница 28: ...sbury Road Oswestry Shropshire SY10 8NN U K Telephone 44 0 1691 664100 www aico co uk Ei Electronics Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 0 61 471277 www eielectronics com...