background image

 

A radio frequency is preset between the EHP crane scale and the USB-Box. This corresponds by default 
to channel 01 (433.075 MHz). The radio frequency can be changed using the "EHP USB-Box Setup Tool" 
software. The tool is available on the driver & firmware CD or as download on ehp.de. 

 

The following table shows the radio frequency of the respective channel numbers. When selecting 
the radio channel, make sure that it is not already occupied by other radio users (e.g. radio crane 
control). 

 

01 

433,075 

15 

434,000 

02 

433,125 

16 

434,075 

03 

433,175 

17 

434,150 

04 

433,225 

18 

434,225 

05 

433,275 

19 

434,300 

06 

433,325 

20 

434,375 

07 

433,400 

21 

434,425 

08 

433,475 

22 

434,475 

09 

433,550 

23 

434,525 

10 

433,625 

24 

434,575 

11 

433,700 

25 

434,625 

12 

433,775 

26 

434,675 

13 

433,850 

27 

434,725 

14 

433,925 

28 

434,775 

Table 2 

 Channel number & Frequency 

 

 

Содержание USB-Box

Страница 1: ......

Страница 2: ......

Страница 3: ...1000 4 11 in accordance with Directive 2004 108 EC electromagnetic compatibility EN 61010 031 Part 1 Safety requirements for electrical equipment for measurement control and laboratory use EN 62368 1...

Страница 4: ...inted specialist company at each periodic inspection Design features of this manual Various elements of this manual have fixed design features This allows you to easily distinguish the following eleme...

Страница 5: ...Figure 2 Technical Data...

Страница 6: ...ing environment Avoid installing this device in an insufficiently ventilated humid or hot place Warning To completely disconnect the device the USB connector must be pulled out of the USB Box To avoid...

Страница 7: ...tenna Installation CD incl driver software USB Box setup tool The warranty is void in the event of Non intended use of the manufacturer s specifications in this operating manual Mechanical damage dama...

Страница 8: ...e drivers can only be performed with administration rights Connect the USB box to a free USB 2 0 port The driver of the USB box is installed automatically under Windows 10 An active Internet connectio...

Страница 9: ...he uninstalled device and select the Update Driver entry Select the Search for drivers on my computer option Select the driver from the CD in the USB_Box Driver folder Then click on Next to start the...

Страница 10: ...Manager with a yellow in the tab Other Devices Click on it with the right mouse button and select the entry Update driver Select the Search for drivers on my computer tab Select the path for the driv...

Страница 11: ...as an entry in the Device Manager our the Ports COM LPT tab Here you will find an entry USB Serial Port COMxx XX COM Port No Note the COM port number for your later application Restart the PC after su...

Страница 12: ...dio frequency of the respective channel numbers When selecting the radio channel make sure that it is not already occupied by other radio users e g radio crane control 01 433 075 15 434 000 02 433 125...

Страница 13: ...ons and the radio connection of the USB Box can be tested safely Copy the folder USB Box Setup Tool from CD to the computer assuming unrestricted read and write rights Then open the program EHP Setup...

Страница 14: ...y pressing the test key on the scale or remote control See also chapter Changing the scale channel setting 7 Read data Delete all Data these keys have no effect on the USB box 8 Path select the path w...

Страница 15: ...individual software program Error free data exchange between the PC system and the scale is only possible under the following conditions Scale is switched on USB Box is connected USB Box driver is ins...

Страница 16: ...nt check is carried out and further information on the balance is displayed The display flashes for approx 5 seconds 8 8 8 8 8 Segment control L A H Software version 1 2 x x Version number Release x x...

Страница 17: ...nally you can also set the channel of the USB box with your own software Send the control command 3x with a time offset of 100ms The channel switching must be done only once when starting the software...

Страница 18: ...N Scale Tare OFF Gross Weight Scale Tara ON Net Weight 10 E 1 2 Single range scale in range I in range II 11 0 1 No stand still Stand still 12 0 1 2 3 4 5 6 7 8 A X E C No button is activated at remot...

Страница 19: ...t 23 Digit 5 Ten thousandths digit of tare value 24 Digit 4 Thousandths digit of tare value 25 Digit 3 Hundreds digit of tare value 26 Digit 2 Tens digit of tare value 27 Digit 1 Unit digit of tare va...

Страница 20: ...as followed With the crane scale switched on press the Power On and TEST buttons simultaneously to open the SETUP menu EEEEE appears on the display Then press the TEST key repeatedly until P13 appear...

Страница 21: ...y until P99 appears in the display Parameter P99 is used to save the changed values Press TARE key to activate the parameter Confirm and close the parameter by pressing the ZERO key Sto Store flashes...

Страница 22: ......

Страница 23: ......

Отзывы: