background image

RCL-CXXW_EHC_Rev.0_05-12-2018 

 

1

/

26

 

 

 

 

 

DSR solaris Electric Heater

  

 

            INSTALLATION

 

OPERATING INSTRUCTIONS 

 

 

         

 

 

 

 

 

 

 

 

 

         

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY  

AND RETAINED FOR FUTURE REFERENCE. 

BE SURE TO OBSERVE ALL 

 LABELS AND WARNINGS  

ON THE APPLIANCE 

 

 

 

 

        500w-1000w-1500w-2000w 

Содержание DSR solaris PSO1000.510.58

Страница 1: ... 1 26 DSR solaris Electric Heater INSTALLATION OPERATING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE 500w 1000w 1500w 2000w ...

Страница 2: ...ed into a fused spur Wi Fi Control DSR Wi Fi Control is our easy to use App based control system To take benefit of this feature you simply need to purchase and connect the heaters to our DSR Gateway The DSR Wi Fi App gives you total control of all your heaters independently or in groups if required The system can be controlled from a Computer Smart phone or Tablet using our Free App Additionally ...

Страница 3: ...Make sure the power cable or other objects do not come into contact with the heater surface while in operation 8 If the power cable becomes damaged it must be replaced by the manufacturer or a suitably qualified trades person Failure to comply may compromise your safety and void your warranty 9 Check the device and the supply cord regularly Do not turn the device on if it is damaged 10 PRECAUTION ...

Страница 4: ...ntail a potential risk to the user and damage the device Use only original accessories 18 Keep all the packaging elements plastic bags cardboard and polyethylene out of the reach of children as they can cause potentially dangerous situations 19 Use this device only for domestic light commercial use and the tasks for which it has been designed This device has not been designed for industrial use It...

Страница 5: ...he device This heater is designed to be connected by plug to the electric installation and fixed to the wall installation Follow the instructions in INSTALLATION Your Guarantee may be invalidated if the installation instructions have not been followed INSTALLATION Heaters can be heavy Take adequate precautions when lifting and maneuvering the heater Always assess the load and seek assistance with ...

Страница 6: ... calculate the correct size of the heater according to the surface of the room We recommend contacting your dealer or engineer to perform this calculation The heater must be placed at a minimum distance of 15cm from any combustible material curtains furniture chairs etc Fig 1 Allow for a minimum distance of 1m from the front of the unit to any obstacles furniture walls curtains for example that co...

Страница 7: ...ans that all circuits within a location containing a bath or shower will require RCD protection not exceeding 30 mA and have the characteristics specified in regulation 415 1 Local isolation should be provided for the heater however the isolation device must be installed out with all zones and in compliance with regulation 701 512 3 and Section 53 of BS7671 Note Heaters must be only installed in o...

Страница 8: ...e heater brackets Use the Screws Plugs provided to fix the brackets to the wall 2 Attach the 2 adhesive spacers onto the heater the back of the heater 3 Hang the heater onto the brackets and lock into position by the screwing the locking device into position Note Take care not to over tighten as this may damage the brackets ...

Страница 9: ...use Spur installed adjacent to the heater This connection unit should comply with BS 1364 4 and have a minimum contact separation of at least 3mm It is recommended when connecting to a screwed terminal that the flex ends are crimped to prevent the copper strands from splaying within the terminal All electrical installation work in particular protective measures must be carried out in compliance wi...

Страница 10: ...770 58 Rated Voltage 230 V 230 V 230 V 230 V Rated Frequency 50 Hz 50 Hz 50 Hz 50 Hz Rated Power Input 500 W 1000 W 1500 W 2000 W Electrical Protection Class II II II II IP Protection Degree IPX4 IPX4 IPX4 IPX4 Dimensions LxHxD mm 380 x 580 x105 510 x 580 x 105 640 x 580 x 105 770 x 580 x 105 Weight kg 5 6 8 7 11 5 14 8 ...

Страница 11: ...s automatically following the Programmed Schedule based on the 3 custom temperatures selected Each LCD Block indicates what temperature is active at that time Manual Mode The Set Temperature only changes if the user modifies it by pressing the and buttons OFF The heater will not heat but can receive remote instructions if linked to a gateway that is connected to the internet ...

Страница 12: ...riginal program settings 2 0 Setting Temperatures At Home Sleeping At Work Away The controller has 3 temperature ranges Comfort Normally when at home Economy Normally used at night or for brief absence periods Frost Protection normally used when away from home To Set Temperatures Now Press Select your temperature change by pressing the buttons then press to confirm Once you have chosen your temper...

Страница 13: ...Day Symbol Indication To start programming 1 Press and hold for 3 seconds 2 Press To select your temperature range followed by to set your times by hour 3 To change the temperature range during programming Press Select temperature then program again using the button ...

Страница 14: ... The next stage is to set the real time Use the and buttons to select the Hour s and Min s save by pressing OK Tip Quick Real Time Setting To change the real time clock without having to go through previous settings Press and hold for 3 seconds to show this screen release and press Config once again to enter Quick Real time settings 4 0 Keypad Locking LOCK Press and Hold the and buttons for 3 seco...

Страница 15: ...emperature unit adjustment ºF ºC C2 Heating control type adjustment Factory Set Do Not Change C3 Temperature compensation adjustment C4 Firmware version C5 Open window detection Stops the heating for 30min if a fall of 2 4ºC is detected over a period of 4 minutes C6 Adaptive Control This feature will turn the heating on early to meet the chosen temperature at the chosen time C7 Full or Manual cont...

Страница 16: ...y go to www electric heatingcompany co uk download dsr Click on New user sign up here Follow the Online instructions to create your account Note Once registered you will be sent a Confirmation email Click on the link to confirm the email to activate your account then sign in If you don t receive an email check your Spam folder You can also setup an account using the free App s that are downloadabl...

Страница 17: ...he router has assigned an IP address to the gateway correctly but there is no communication with the server Orange on alternating with green flashing briefly every 5 seconds the Gateway has connected to the router correctly and has internet connection Note It is preferable to register your account and gateway before installing it If it is registered after installation it may take a few minutes to ...

Страница 18: ...tage For each additional new device that is added the available time increases as you go through the pairing process Pairing a Heater with the Gateway When the Gateway is in pairing mode Simply press and hold the OK button on the heater for 3 seconds until the Link symbol appears your heater is now connected and ready to program through the App 9 0 Optional Power Meter Note Installation of this de...

Страница 19: ...aximum Available Load for your property protecting the incoming electrical supply If your Max Power Setting has been achieved i e another high power electric appliance like an electric shower is in use The heating systems output will be temporarily reduced by the equivalent power of the appliance in use until it is switched off Pairing the Power Meter You can simply pair the power meter in the sam...

Страница 20: ...il 2 heaters in operation have reached their desired temperature setting Once this has been achieved the 2 disabled heaters would then become active You can also setup heater priorities within the heater settings if you would like specific heater or heaters to come on first Typical Power Meter Wiring Layout Note Installation of this device must be carried out by a competent electrician in accordan...

Страница 21: ... Electric self consumption metering 3 error Transformer less power stage Max power 16A Gateway External Power Supply Voltage 5V 500mA Consumption 300mA Connector Type RJ45 Ethernet connector LED indicator conditions 868Mhz RF integrated PCB antenna Micro USB Adaptor included Ethernet 0 5m cable included Power Meter DIN Rail Mount mini enclosure required External current sensor 3 5 mm jack connecto...

Страница 22: ...tric Heaters The 5 year guarantee applies to the body of the heater only The electrical and electronic components of the heater have a 2 year guarantee The period of guarantee commences with the day of delivery If within the guarantee period the heater is defective due to faulty components or workmanship we undertake to repair the heater free of charge Depending on the circumstance of the fault we...

Страница 23: ...equirements for health and safety of European Directives 2014 30 UE EMC DIRECTIVE 2014 35 UE LV DIRECTIVE 2011 65 UE RoHS DIRECTIVE 2014 53 EU RED 2009 125 EC ErP Directive With reference to the application of the following standards 2014 30 EU EMC DIRECTIVE EN 55014 1 2006 A1 2009 A2 2011 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55014 2 1997 AC 1997 A1 2001 A2 2008 EN 61000 4 2 2009 EN 61000 4 3 20...

Страница 24: ...0008 kW 0 0008 kW At minimum heat output el max 0 0008 kW 0 0008 kW 0 0008 kW 0 0008 kW In standby mode el SB 0 0008 kW 0 0008 kW 0 0008 kW 0 0008 kW Type of heat output room temperature control Electronic room temperature control plus week timer Other control options Room temperature control with open window detection With adaptive start control Distance control option Electric Heating Company Bl...

Страница 25: ...l containers they have to be collected separately to optimise the recycling of the components and materials that comprise it and reduce the impact on human health and the environment The crossed out wheeled bin is marked on all Electrical and Electronic products to remind the consumer of their obligation dispose of them separately The consumer must contact the local authority or the vendor to lear...

Страница 26: ...12 2018 26 26 The Electric Heating Company Limited Unit 40 Block 5 Third Road Blantyre Industrial Estate Glasgow G72 OUP Tel 01698 820533 Fax 01698 825697 info electric heatingcompany co uk www electric heatingcompany co uk ...

Отзывы: