Installation
Page 25
Connecting the exhaust hose
Within the EFOY Pro fuel cell methanol and oxygen are converted into wa-
ter and carbon dioxide. This process creates heat, which needs to be con-
ducted to the outside together with water vapor, carbon dioxide, and traces
of methanol.
WARNING!
It is essential that the carbon dioxide is conducted into the open air via a
hose.
Therefore connect the included exhaust hose and always evacuate the ex-
haust gases from the installation space or site to the outside.
Exhaust gases contain moisture and may exceed 60°C / 140°F during op-
eration. This constitutes a scalding hazard. The exhaust gases may con-
tain substances that are harmful to health. Avoid inhaling exhaust gases
directly or for extended periods. The insulated exhaust hose must be
vented outside.
It is possible to also collect the generated water in the installation space in
a separate, vented water cartridge.
1.
Remove the protective cap from the
exhaust gas outlet of the EFOY Pro
fuel cell. Keep this for winter storage
or in case you need to return the fuel
cell.
2.
Attach the exhaust hose supplied to
the exhaust gas outlet.
3.
Take measurements to determine
where to drill the duct opening.
The duct opening should consist of a
hole with a 1 cm / 0.4 in diameter.
4.
Drill a hole for the exhaust hose.