- AB AB600A5015
Instruction Manual
- 19 -
6.14 Starting Characteristics
Function
Parameters
Starting edge
(ALF)
220
The drive acceleration dynamics can be adapted to the sewing machine characteristic (light/heavy).
High setting value = high acceleration
With a high starting edge setting and, in addition, possibly high braking parameter values on a light machine, the
characteristic may appear coarse. In this case, one should try to optimize the settings.
6.15 Operating hours counter
Function
Parameters
Acoustic signal (operating part)
Service routine for total operating hours
Service routine for operating hours before service
Input of operating hours before service
(AkS)
(Sr6)
(Sr7)
(Sr)
127
176
177
217
The integrated operating hours counter records the time of motor operation. Downtimes are not recorded. Time
recording accuracy is 1ms. There are two ways of operating hours counting.
1. Basic operating hours counting:
217 =0
Operational mode: Operating hours counting
2. Service Hours Monitoring:
217 =>0
Operational mode: Number of operating hours before the next service.
Input of operating hours before the next service.
This value is compared to the operating hours counter.
The input of hours is done in steps of 10. i. e. the lowest display of 001 corresponds to 10 hours
(e. g. 055 = 550 hours).
When the set number of operating hours are reached, the message "C1" will show on the display
after each trimming operation. In addition, the speed indicator blinks on the during operation or
after drive standstill..
176
In this service routine, the total operating hours can be read out according to the procedure
example described below for parameter
177
.
177
Display of operating hours since the
last
service.
Display example of operating hours or hours since the last service and operating hours counter reset.
Display on the control:
Select parameter
177
Press the
E
key
Sr7
Press the
>>
key
h t
(hours /thousands letter symbol)
Press the
E
key
000
hours /thousands display)
Press the
E
key
h h
(hours / hundreds letter symbol)
Press the
E
key
000
(hours / hundreds display)
Press the
E
key
Min
(minutes letter symbol)
Press the
E
key
00
(minutes display)
Press the
E
key
SEc
(seconds letter symbol)
Press the
E
key
00
(seconds display)
Press the
E
key
MS
(milliseconds letter symbol)
Press the
E
key
000
(milliseconds display)
Press the
E
key
rES
See chapter "Set and Reset Operating Hours Counter"
Press the
E
key
The process will be repeated from the hours display.
Press the
P
key twice
e.g.
400
(sewing process can be started)
Содержание AB600A5015
Страница 5: ... AB AB600A5015 Instruction Manual 5 ...
Страница 60: ......
Страница 61: ...Instruction Manual with parameter List Distribution For your notes ...
Страница 62: ... Parameter list 94 For your notes ...
Страница 63: ... AB620A5030 5032 Parameter list 95 For your notes ...