EFILive AutoCal V3 Скачать руководство пользователя страница 1

Knowledgebase > V8 Scan and Tune Software > 

Device Settings

Device Settings

EFILive Support - 2020-07-10 - 

Comments (0)

 - 

V8 Scan and Tune Software

Device Settings manage a range of user configuration options for FlashScan and AutoCal
hardware.  Device settings can be accessed via EFILive V8 Scan and Tune software, or via
FlashScan and AutoCal menus.

Device Setting Configuration

There are 2 different methods to access Device Settings.  To access these;

Connect your FlashScan or AutoCal to your PC.

1.

Open the EFILive V8 Scan and Tune application, and then select either:

2.

Select the [F6: Devices] option in the left-hand pane; or

1.

Select the [F5: BBX] -> [F6: Quick Setup] menu and select the correct

2.

hardware option from the Edit AutoCal V3 Settings button.

Both menu options perform the same function, however the option via the [F5: BBX] ->
[F6: Quick Setup]
 allows these settings to be programmed in a single process along with
all other BBX settings, including scan and tune configurations, along with tune files.  The
option via [F6: Devices] only programs device settings.  Other BBX settings need to be
programmed independently.

SD Card, Date Format, Timing and LED Mode Configuration

Navigate to the Device Settings option using either of the above methods;

Select [F2: General] to manage the following options:

1.

Target Device - select the device to programmed if multiple devices are

1.

connected to your PC.  Making this selection activates options applicable for

the chosen device, and deactivates options that are not applicable to the

chosen device.

File System - configures FlashScan V2 to use either internal memory or 

SD

2.

Card

.

Date format - US Style or Australian Style.

3.

Timing - Low Power notification, length of time Splash screen displays.

4.

LED Mode - configures status display, visual alarm or none.

5.

Содержание AutoCal V3

Страница 1: ...n however the option via the F5 BBX F6 Quick Setup allows these settings to be programmed in a single process along with all other BBX settings including scan and tune configurations along with tune files The option via F6 Devices only programs device settings Other BBX settings need to be programmed independently SD Card Date Format Timing and LED Mode Configuration Navigate to the Device Settings o...

Страница 2: ...y Configuration Navigate to the Device Settings option using either of the above methods Select F3 Display to manage the following options 1 Units Metric or Custom display units 1 Inverse Display sets screen color combinations for FlashScan V2 2 Data Logging Display sets the number of PID s per page display for 3 FlashScan V2 Contrast Adjustment adjusts the contrast for FlashScan V2 with a blue 4 c...

Страница 3: ...s and Program Quick Setup Keypad Configuration Navigate to the Device Settings option using either of the above methods Select F4 Keypad to manage the following options 1 Keypad Auto Repeat 1 Display Timeouts 2 Select appropriate options 2 Program FlashScan or AutoCal using the Program option or 3 Select Close to return to the Quick Setup select Include current device 4 ...

Страница 4: ...logging Common Settings set EFILive s FAST CAN Mode for GM controllers and 4 Dodge Cummins Fast CAN Mode Select appropriate options 2 Program FlashScan or AutoCal using the Program option or 3 Select Close to return to the Quick Setup select Include current device 4 settings and Program Quick Setup Logging Configuration Navigate to the Device Settings option using either of the above methods Select...

Страница 5: ...ve methods Select F7 BBX to manage the following options 1 BBL PID validation configuration for FlashScan AutoCal V2 1 BBR and BBF verification and display options 2 Perform extended verification of uploaded file 1 Display OBDII retry statistics after Read Flash is complete for 2 FlashScan V2 Display folders when selecting tune files for flashing 3 Automatically save trace files if read or flash fails 4 B...

Страница 6: ...uration Navigate to the Device Settings option using either of the above methods Select F8 Serial I O to manage the following options 1 Serial COM Port Setup select None Wide Band or External Data Logger 1 Wide Band Display Layout set format and data display for FlashScan V2 2 Wideband Type select from a list of supported Wide Band devices 3 Select appropriate options 2 Program FlashScan or AutoCa...

Страница 7: ... Custom Imperial 4 Set MRU PIDs Yes or No 5 Set Scan Rate Fast Medium or Slow 6 Set Note 30 Yes or No 7 Set Fast CAN Yes or No 8 Set Skip Verify Yes or No 9 Set Verify BBR Yes or No 10 Set BBX Status Yes or No 11 Set BBX Directory Yes or No 12 Set Switches enables switchable tuning on simple menu Yes or No 13 Set Trace Yes or No 14 Set COM Port Wideband O2 External or Unknown 15 Set WO2 Type selec...

Страница 8: ...d time settings 2 Browse Files view files saved on the AutoCal 3 Delete Files deletes files on the AutoCal 4 Free Space displays used and available space 5 Format File Sys Formats the file system 6 Related Content Configure FlashScan and AutoCal for BBX Wide Band Configuration SD Card Configuration AutoCal V2 Device Settings FlashScan V2 Device Settings V3 Device Settings FlashScan V2 Screen Contrast ...

Отзывы: