Installation and Service Guide: Printer Controller EB-34
Performing Backup and Restore
3
From “What do you want to do?” screen, select
Restore from backup or recovery partition
.
The
Select
backup source dialog appears. You can choose one of the following:
•
Backup
If present, previous backups are listed for you to choose.
•
Restore from recovery partition
This restores the server from a hard disk drive partition to its factory-built settings. It takes approximately one
hour to complete the restoration.
•
Search for backups from this system
This lets you select a backup from a displayed list. Alternatively, you can select
Refresh
,
Import
backup history
,
or
Search the network for backups
.
If a backup image exists, the installer lists information about each backup image:
•
The time and date in which you created the backup.
•
The location of the backup image: Local Disk, USB drive, External hard disk drive, or Network.
•
Alternatively, you can also choose to
Refresh
,
Import backup history
, or
Search network
.
4
Select the source of the backup and click
OK
.
When a message appears indicating that all the data will be erased, click
Continue
to proceed the restore.
Using bootable backup media to restore
Use the following procedure when you restore the system without using the System Software DVD 1, or when the EB-
34 does not boot from the built-in hard disk drive. You can use this procedure when you replaced the HDD with a new
one.
You can restore from the bootable backup media (including the Fiery factory image) created by either Fiery System
Installer or Fiery System Restore.
To restore the system from bootable backup media
To restore from the bootable media, you must have created a backup with the “Create bootable media” option. If you
have created a backup as bootable backup media, follow these instructions. You can use this procedure to install the
system software after you replaced the new hard disk drive.
1
Shut down the EB-34.
Important:
Any custom settings you have specified after installation are over-written.
Important:
This procedure requires a monitor, mouse, and keyboard to be attached to the EB-34.