background image

I.  MOUNTING THE UNIT

1) The unit should be mounted as close to the point of use as possible.

Do not install the heater above a faucet or “point of use” because the siphoning effect may  
drain the heater which can cause premature element burn out.

2) This unit must only be mounted in a vertical position with the 

water fittings located at the

bottom of the unit

. Mounting other than in the vertical position 

WILL

cause element burn 

out and cause permanent damage to the water heater.

3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side.

Under 

NO

circumstances can these be reversed.

4) Leave a minimum of 8” above the unit for easy replacement of the element.

5) The heater should be fixed to the wall using all four mounting holes of the backplate.  Unit 

weight is approximately 15 lbs.  Use an appropriate fastener for this weight.  For the unit to
be mounted against hollow walls, suggest using steel wall anchors, with the correct grip
range and #6-32 screw size minimum.

NOTE: The heater should be installed below the level of all hot water outlets serviced by this

heater.

NOTE: PRESSURE AND TEMPERATURE RELIEF VALVE

These units are not required by UL to have a Pressure and Temperature Relief
Valve (PTRV). You should check with local codes to find out if one is required in your
area.  If local codes require the use of a temperature and pressure relief valve it
should be installed on the outlet hot water pipe before the outlet ball valve.

Figure 2

3

Requirements:

Output: 38 kW  @ 240 volts

32 kW @ 220 volts

About 0.85-4.0 GPM at showering temperature.
Best used when operating one or two outlets
at a time.

Showers and the whole house, cabin or condo

MODELS: 

EX380T2T2

Eemax

Lavatory

Shower

Kitchen

Hot outlet

Cold inlet

Содержание EX380T2T2

Страница 1: ...ILL NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE READ ALSO THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INST...

Страница 2: ...20 240V CIRCUITS USING CORRECTLY RATED WIRES AND CIRCUIT BREAKERS WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR FURTHER INFORMATION FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY WARNING WARNING WATER HEATERS EQUIPPE...

Страница 3: ...the backplate Unit weight is approximately 15 lbs Use an appropriate fastener for this weight For the unit to be mounted against hollow walls suggest using steel wall anchors with the correct grip range and 6 32 screw size minimum NOTE The heater should be installed below the level of all hot water outlets serviced by this heater NOTE PRESSURE AND TEMPERATURE RELIEF VALVE These units are not requi...

Страница 4: ...UM 8 CLEARANCE ABOVE UNIT 4 Figure 1A MOUNTING HOLES To 4 Independent circuit breakers serial LUG TERMINALS AT RELAYS ELECTRICAL HOOK UP 220 240 V L1 L2 C B 2 L1 L2 C B 3 L1 L2 C B 4 L1 L2 C B 1 GROUND LUGS ...

Страница 5: ... tape only No pipe dope NPT Elbow s Union Threaded type Teflon tape only No pipe dope NOTE When soldering pipe joints remove heater from the wall Serious damage can occur if any soldering is done while pipes are connected to the heater Take care to ensure that the pipes are correctly aligned with the inlet and outlet bosses in order to avoid excessive stress on the heater body molding Pipe support...

Страница 6: ...cting the heater Failure to do so could cause damage to the flow switch 3 Install isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes Fig 1B 4 When all plumbing is complete fully check the system for water leaks at all the plumbing connections If a leak is present take corrective action Fully open both inlet and outlet ...

Страница 7: ...vided in the flange on the backplate The live wires should be connected to the slots in the terminal block marked L1 and L2 The ground lead must be connected to the slot marked GND GROUND MUST BE BROUGHT TO THE GROUND AT THE CIRCUIT BREAKER PANEL DANGER FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY Units rated of 240 V can operate at 220 V with reduced output The output will v...

Страница 8: ...ections the first unit is the right hand heating module and the second unit is the right center far left hand is the forth heating module IV COMMISSIONING YOUR HEATER T2T2 MODELS a Switch on the power to the first unit The power indicator light should illuminate b Switch on the power to the second unit again the power indicator lights should illuminate Note These lights should pulse On and Off at ...

Страница 9: ...When it is pulsing the unit is modulating the power to achieve the temperature set by means of the temperature adjustment screw ALL HEATERS In order to obtain good control at single lever mixer type faucets single spout the cold water supply to the faucet should be restricted to give approximately the same flow rate of cold water to the faucet as the hot water coming from your Eemax heater The sim...

Страница 10: ...lement 5 ECO TRIPPED High Limit Thermostat TURN OFF THE FOUR MAIN CIRCUIT BREAKERS Reset by pushing in red button on each heater module SYMPTOM B NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON 1 WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve See page 9 for temperature rise at various flow rates 2 INCORRECT POWER SUPPLY Make sure that the unit is connected to the voltag...

Страница 11: ...HEATER CORE ASSEMBLY EEMAX REPLACEMENT PARTS DIAGRAM CONTROL BOARDS 7 Wire EX 100G EEMAX INC 353 Christian Street Oxford CT 06478 Tel 203 267 7890 11 To 4 Independent circuit breakers serial 8 Wire EX 284 ECO High Limit Thermostat Push to Reset ...