EN537 Smart Encoder
9
Copyright © 2018 EEG Enterprises, Inc.
All Rights Reserved.
Other Live Captioning Methods
Modem (Optional Add-on)
Standard RJ-11 connection. Connect to a phone line to enable dial-up captioning and provide your captioner
with the telephone number associated. Using a PBX or other digital non-POTS system is NOT recommended
- many of these are not compatible with modem communications. Once connected, the LED on the front
panel of your encoder labeled “MDM” will turn green.
Telnet
Enable telnet via the encoder’s web interface and select a port. Configure your firewall to allow a captioner
to get to your encoder on the designated port and then give your caption service provider the port number
and public IP address.
RS-232 / RS-422 (Teleprompters or Other Devices)
See hardware section for cabling detail. Serial port settings are controlled through the web interface of the
encoder by selecting
Serial Ports
from the left side menu or by navigating to
System Setup > P1 Mode
from
the front panel LCD menu of the encoder. The EN537 supports RS-232, RS-422, and RS-422 Sony (with RS-
422 and RS-422 Sony options configurable on Port 1 only). Default settings are 1200 baud, odd parity, and
7 data bits. Customized settings are sticky after power cycles. Modem will automatically take priority when
active so that the prompter can be overridden as desired.
Figure 4: Serial Port Settings in the Web Interface