EDWARDS

®

 Catalog 

u

 Intelligent Input-Output

12-18-17

12-18-17

L I F E   S A F E T Y  

&  

I N C I D E N T   M A N A G E M E N T

Overview

SIGA-CC2A and SIGA-MCC2A Single/Dual Input Signal Mod-
ules are part of EDWARDS's Signature Series system. They are 
intelligent analog addressable devices used for connecting, upon 
command from the loop controller, supervised Class A or Class B 
signal or telephone circuits to their respective power inputs. 

Module power inputs may carry polarized 24 Vdc current to oper-
ate audible and visible signal appliances, or 25 and 70 V

RMS

 to 

operate audio evacuation speakers and firefighter’s telephones. 
The SIGA-CC2A/MCC2A may be configured as a three-state or 
four-state telephone riser selector.

The loop controller assigns an address to the module automati-
cally. No addressing switches are used. A custom address can be 
assigned using a laptop computer. 

Diagnostic LEDs provide visible indication of the status of the 
module when the cover plate is removed:

• Normal — green LED flashes
• Alarm/active — red LED flashes

The CC2A mounts in a two-gang electrical box. The MCC2A 
plugs into a UIO motherboard. Both modules provide the same 
functionality.

The actual operation of the module is determined by the “person-
ality code” selected by the installer. It is downloaded to the module 
from the Signature loop controller during system configuration.

 Standard Features

•  Class A or B Operation
•  Supports three- and four-state telephones
•  Dual input (riser) select

 

Use for connecting supervised 24 Vdc Audible/Visible signal 
circuits, or 25 and 70 VRMS Audio Evacuation and Telephone 
circuits to their power inputs.

•  Ring-tone generator

 

When configured for telephone circuits, the SIGA-CC2A/MC-
C2A generates its own ring-tone signal eliminating the need for 
a separate ring-tone circuit.

•  Plug-in (UIO) or standard 2-gang mount

 

UIO versions allow quick installation where multiple modules 
are required. The 2-gang mount version is ideal for remote 
locations that require a single module.

•  Automatic device mapping

 

Signature modules transmit information to the loop controller 
regarding their circuit locations with respect to other Signature 
devices on the wire loop.

•  Electronic addressing

 

Programmable addresses are downloaded from the loop con-
troller or a laptop PC; there are no switches or dials to set. 

•  Ground fault detection by address

 

Detects ground faults right down to the device level.

Signal Modules 

with Class A 

Operation

SIGA-CC2A, SIGA-MCC2A

SIGA-MCC2A

SIGA-MCC2A

SIGA-CC2A

7300-1657: 

0252

S3424

Содержание SIGA-CC2A

Страница 1: ...board Both modules provide the same functionality The actual operation of the module is determined by the person ality code selected by the installer It is downloaded to the module from the Signature loop controller during system configuration Standard Features Class A or B Operation Supports three and four state telephones Dual input riser select Use for connecting supervised 24 Vdc Audible Visib...

Страница 2: ...perates as a riser selector for a four state open normal active trouble firefighter s telephone Only one telephone can be used with the CC2A at any given time When a telephone handset is plugged into its jack or lifted from its hook the module generates its own ring tone signal A separate ring tone riser is unnecessary The module sends this signal to the control panel to indicate the presence of a...

Страница 3: ...s each device on the loop and assigns a soft address to each serial number If desired the modules can be addressed using a laptop computer No addressing switches are used Warnings Cautions These modules do not provide supervision of the riser The fire alarm panel must provide this function These modules do not support conventional 2 wire smoke detec tors These modules will not operate without elec...

Страница 4: ...oller Installation Sheet for wiring specifications 4 These modules will NOT support two wire smoke detectors 5 All wiring power limited and supervised If the input source is non power limited then maintain spac ing of 1 4 inch or use FPL FPLP FPLR or equivalent in accordance with NEC 6 The SIGA UIO6 does not come with TB8 through TB13 7 Supervised and power limited 8 Supervised and power limited w...

Страница 5: ...oltage 20 VDC Current Standby 310 µA Alarm 135 µA Ground fault impedance 10 k Ohms Wire Size 12 to 18 AWG 2 5 to 0 75 sq mm Maximum line impedance Refer to the installation manual for your fire alarm control panel Output rat ings special applications 24 VDC 2 A 25 VAC audio 50 W 70 VAC audio 35 W EOL resistor value 47 kΩ Max circuit resistance Refer to manual Max circuit capacitance 0 1 µF Operati...

Страница 6: ...sue 1 12 18 17 12 18 17 LIFE SAFETY INCIDENT MANAGEMENT Contact us Email edwards fire fs utc com Web edwards fire com 1016 Corporate Park Drive Mebane NC 27302 EDWARDS is a registered mark in the United States and other countries 2018 United Technologies Corporation All rights reserved ...