Figure 9 Sight-glass assembly
CS
/11
11/
A
1
1
2
3
4
5
1. Screws (2 off M6 x 20)
2. Bezel
3. Sight-glass
4. O-ring
5. Oil-box
1. Screws (2 off M6 x 20)
2. Bezel
3. Sight-glass
4. O-ring
5. Oil-box
6.8 Clean the motor fan-cover and enclosure
If the motor fan-cover and enclosure are not kept clean, the air-flow over the motor can
be restricted and the pump may overheat.
1.
Switch off the pump and disconnect it from the electrical supply.
2.
Use a dry cloth and a soft brush to remove dirt and deposits from the fan-cover
and enclosure.
6.9 Clean and overhaul the pump
Clean and overhaul the pump as described in the instructions supplied with the clean
and overhaul kit (see
on page 51).
6.10 Fit new blades
Fit new blades to the pump as described in the instructions supplied with the blade kit
on page 51).
03/2021 - ©Edwards Limited
Page 45
A65201880_AA
A65201880_AA - Maintenance
Содержание RV12
Страница 58: ...This page has been intentionally left blank ...
Страница 62: ...This page has been intentionally left blank ...
Страница 63: ...This page has been intentionally left blank ...
Страница 64: ...edwardsvacuum com ...