Figure 4 Motor voltage configuration: single-phase pumps
1
2
3
B
4
C
8
7
5
6
B
C
CS
/110
8/
A
A
A. Top view of motor
B. View of voltage selector switch cover
C. View of On-off switch
A. Top view of motor
B. View of voltage selector switch cover
C. View of On-off switch
1. Terminal box
2. Electrical inlet-connector
3. Voltage selector switch
4. On-off switch
5. Voltage selector switch cover
6. Retaining screws
7. Position 'I' (on)
8. Position '0' (off)
1. Terminal box
2. Electrical inlet-connector
3. Voltage selector switch
4. On-off switch
5. Voltage selector switch cover
6. Retaining screws
7. Position 'I' (on)
8. Position '0' (off)
4.7 Electrical installation: three-phase pumps
4.7.1 Check and configure the motor
CAUTION:
Ensure that the motor is correctly configured for the local electrical supply. If the
pump is operated when the motor is not correctly configured for the electrical supply,
the motor will be damaged.
1.
Remove the screws which secure the cover of the motor terminal-box. Remove the
cover.
2.
Remove the cable-gland from the inside of the terminal-box and fit the cable-gland
to the cable lead through hole in the side of the terminal-box.
3.
Ensure that the motor is correctly configured for the local electrical supply. If
necessary, reconfigure the links (
Figure: Three-phase electrical connections: 200–
03/2021 - ©Edwards Limited
Page 29
A65201880_AA
A65201880_AA - Installation