3. Technical data
3.1 Operating and storage conditions
Table 3 Operating and storage conditions
Range
Data
Ambient operating temperature range
5 °C to 40 °C
Ambient operating humidity range
10% to 90% RH (non
‑
condensing)
Maximum operating altitude
2000 m
Ambient storage temperature range
-30 °C to 70 °C
Pollution degree
2
Equipment type
Indoor use
Enclosure protection
IP20
Note:
The nXLi pump-system is designed to meet the electrical safety creepage and clearance
requirements for 3000 m altitude. For maximum thermal performance, de-rating is
required between 2000 m and 3000 m. Reduce the maximum operating ambient
temperature from 40
o
C to 35
o
C between 2000 m and 3000 m linearly. This de
‑
rating
meets the requirements of IEC 282
‑
1.2.
Table 4 Mechanical data
Parameter
nXL110i
nXL200i
Overall dimensions (L x W x H)
654 x 308 x 344 mm
704 x 308 x 343 mm
Maximum tilt angle
25°
Nominal rotational speed
9000 rpm
Mass
78 kg
84 kg
Inlet connection
NW40 or NW50
Outlet connection
NW25