Fault
The pumping speed is poor
Cause
The connecting pipelines are too small or too long in diameter.
Remedy
Connect the pump using suitable length pipelines with the correct diameter.
Cause
The inlet filter is blocked.
Remedy
Clean or replace the inlet filter.
Fault
There is an external oil leak
Cause
The outer shaft seal is worn or damaged.
Remedy
Replace the seals as supplied in the clean and overhaul kit or return the pump to our
service centre for repair.
Cause
The oil box gaskets have deteriorated.
Remedy
Replace the seals as supplied in the clean and overhaul kit or return the pump to our
service centre for repair.
Cause
There is an oil leak from the gas ballast control.
Remedy
Replace the seals as supplied in the clean and overhaul kit or return the pump to our
service centre for repair.
Cause
There is an oil leak from the drain plug.
Remedy
Replace the seals as supplied in the clean and overhaul kit or return the pump to our
service centre for repair.
Cause
There is an oil leak from the sight glass.
Remedy
Replace the seals as supplied in the clean and overhaul kit or return the pump to our
service centre for repair.
Fault
Any other problems
Cause
Fault conditions other than the ones previously mentioned.
Remedy
Contact us or the supplier.
8.1 Alarm indicator codes
Whenever a fail condition becomes active the red alarm indicator shows a flashing
sequence. If the error light is on continuously this indicates a problem has been found
with the embedded software. In this case, try cycling the power. If cycling the power
does not clear the indication, a software download may be required. In this situation,
contact us or the supplier. If the alarm indicator is flashing, identify the error flash code
and consult
Table: Flashing error codes on page 77
There is a sufficient off period between each subsequent cycle repetition to clearly mark
the start of a new flash sequence. The duration of a long flash (L) is equal to 3 times the
duration of a short flash (0.5 seconds).
Page 76
A65901880_D - Fault finding
Содержание nRVi
Страница 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Страница 6: ...This page has been intentionally left blank...
Страница 97: ...Page 93 A65901880_D Service...
Страница 98: ...This page has been intentionally left blank...
Страница 99: ...This page has been intentionally left blank...
Страница 100: ...edwardsvacuum com...