Table 25
Power limit setting
Maximum value setting
Minimum value setting
Default power setting
120 W
50 W
80 W*
* This is the most common setting. Some specific customer pump options may have a
different value. Refer to
on page 11 for more details.
Send the command as follows (the 'd' characters shows the value in Watts that will be
set. For example, to set the limit to 90 W, type 90).
Command
!
S
8
5
5
sp
d
d
d
cr
The reply is as follows:
Reply
*
S
8
5
5
sp
r
cr
The Power Limit Setting is now stored in the memory of the pump.
To check what power limit is set, send a query as follows:
Command
?
S
8
5
5
cr
The reply as follows:
Reply
=
S
8
5
5
sp
d
d
d
cr
5.1.4 Power supply to the fan from the motor controller
The motor controller on auxiliary output 2 can supply the power to the fan.
Send the command that follows:
Command
!
S
8
6
4
sp
8
cr
The reply is as follows:
Reply
*
S
8
6
4
sp
r
cr
The permanently enabled fan setting is now stored in the memory of the pump.
When the pump is shipped, it is set up to operate a vent valve. Send a query that follows
to find the setting:
Command
?
S
8
6
4
cr
The reply is as follows:
Reply
*
S
8
6
4
sp
d
cr
If the character 'd' is 8, the fan is enabled. If the character 'd' is other than 8, configure
the motor controller to operate the fan.
5.1.5 Controlled venting options
A number of vent options are available if you use the motor controller to automatically
control a vent valve.
Refer to
for available venting options. Refer to
for available valve types.
07/2021 - ©Edwards Limited
Page 64
B8G000880_E
B8G000880_E - Configuration