3.5 Nitrogen purge data
Table 5
Nitrogen purge data
Characteristics
Units
Rating
Nitrogen supply pressure range
bar gauge
2.5 - 6.9
psi gauge
36 - 100
Nitrogen supply quality
*
Nitrogen inlet connection
1/4 inch tube fitting
* It is the customer's responsibility to make sure the pump purge gas is correct for the
process gases and by-products being pumped. Where nitrogen is used as a purge gas, it
should be normal industrial grade liquid nitrogen, or an equivalent standard, with an
oxygen and water content no more than 4 ppm.
Table 6
Gas module types and flows
Varimode 96 (Standard)
Mode
Pump
condition Flow condition
Settable stages flow
range
Fixed flow
Total
flow
4/5
5/6
6/7
Exh
SS
Off
Off
Nominal individual flow
0
0
0
0
0
0
Total flow
0
Green
Running
Nominal individual flow
0
0
0
0
4
4*
Total flow
0
On-Min
Running
Nominal individual flow
1
3
4
4
4
16
Total flow
8
On-Nominal Running
Nominal individual flow
2
15
19
4
4
44
Total flow
36
On-Max
Running
Nominal individual flow
5
37
46
4
4
96
Total flow
88
* Nitrogen flow reduction during Green Mode requires special configuration. Contact the supplier for
advice on application and activation.
3.6 Electrical data
Table 7
Pump electrical data
Characteristics
Units
3000
1200
1200T
1200TX
600
600T
200
200T
Rated system input power at maximum load
kW
4.7
4.8
4.8
3.0
Dry pump motor rating
kW
1.9
1.9
1.9
1.9
Mechanical booster motor rating
kW
4.5
1.9
1.9
-
10/2020 - ©Edwards Limited
Page 18
M56635880_D
M56635880_D - Technical data
Содержание iXM Series
Страница 1: ...Dry Pump System iXM INSTRUCTION MANUAL M56635880_D Original instructions edwardsvacuum com...
Страница 101: ...This page has been intentionally left blank...
Страница 102: ...This page has been intentionally left blank...
Страница 103: ...This page has been intentionally left blank...
Страница 104: ...edwardsvacuum com...