Edwards EPS 800 Скачать руководство пользователя страница 1

EPS 800 Power supply

INSTRUCTION MANUAL

B8J204880_B
300903164_002_C1

Original instructions

edwardsvacuum.com

Содержание EPS 800

Страница 1: ...EPS 800 Power supply INSTRUCTION MANUAL B8J204880_B 300903164_002_C1 Original instructions edwardsvacuum com...

Страница 2: ...e content As far as practical we have ensured that the products have been designed and constructed to be safe and without risks when properly installed and used in accordance with their operating inst...

Страница 3: ...2 Ordering information 5 2 3 Accessories 5 2 4 Technical data 5 3 Installation 7 3 1 Use as a benchtop unit 7 3 2 Installation to the pump 7 4 Operation 10 4 1 Start up 10 4 2 Shut down 10 4 3 Mainten...

Страница 4: ...shock and damage to the equipment Make sure that the mains power supply is switched off before you connect or disconnect the mains cable The EPS 800 must only be opened by certified Edwards Service Ce...

Страница 5: ...r EPS 800 2 5 m long with Euro plug with US plug 5 15 P with UK plug Mains input socket only B8J200829 B8J200830 B8J200831 B8J200833 Bracket for mounting to the pump washers and bolts enclosed B8J2008...

Страница 6: ...amination grade 2 Resistance to interference 61000 6 2 Industry Interference sourcing 61000 6 3 Household Maximum operating altitude 2000 m above sea level without any power derating 2000 m up to 3000...

Страница 7: ...2 Attach the bracket with the power supply unit to the pump Refer to Figure Mount the bracket to the pump If there is no air cooler attach the bracket using 4x M5x14 bolts washers and spring washers a...

Страница 8: ...Figure 4 Mount the bracket to the power supply BC 0023 B 06 2021 Edwards Limited Page 8 B8J204880_B 300903164_002_C1 B8J204880_B Installation...

Страница 9: ...Figure 5 Mount the bracket to the pump BC 0029 B 06 2021 Edwards Limited Page 9 B8J204880_B 300903164_002_C1 B8J204880_B Installation...

Страница 10: ...mp operating instructions for information The turbomolecular pump will start only when the mains cable is plugged and a start command is provided 4 2 Shut down To shut down the EPS 800 do the steps th...

Страница 11: ...quirements of UL 61010 1 2012 CSA C22 2 No 61010 1 12 cTUVus Certificate No CU 72204401 01 cTUVus File No 32084633 001 The T V Rheinland of North America is a Nationally Recognised Testing Laboratory...

Страница 12: ...d on the relevant requirements of harmonised standards EN 61010 1 2010 A1 2019 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61326 1 2...

Страница 13: ...This page has been intentionally left blank...

Страница 14: ...This page has been intentionally left blank...

Страница 15: ...This page has been intentionally left blank...

Страница 16: ...edwardsvacuum com...