A705-40-880 Issue B
Page 26
© Edwards Limited 2011. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
Figure 5 - Flange loading limits
1. Pump-inlet
2. Pump-outlet
F. Force
M. Moment
R. Resultant
X. Load orientation
Y. Load orientation
Z. Load orientation
Maximum force
Pump-inlet
Pump-outlet
FX
±
530 N
±
120 lbf
±
357 N
±
80 lbf
FY
±
446 N
±
100 lbf
±
290 N
±
65 lbf
FZ
±
669 N
±
150 lbf
±
446 N
±
100 lbf
FR
±
959 N
±
215 lbf
±
647 N
±
145 lbf
Maximum moment
Pump-inlet
Pump-outlet
MX
±
476 Nm
±
350 lbf ft
231 N m
±
170 lbf ft
MY
±
360 Nm
±
265 lbf ft
177 N m
±
130 lbf ft
MZ
±
238 Nm
±
175 lbf ft
115 N m
±
85 lbf ft
MR
±
645 Nm
±
475 lbf ft
313 N m
±
230 lbf ft